作 者:王昂 戴石良(指导) 高现磊 WANG Ang;DAI Shiliang;GAO Xianlei(School of Civil Engineering,University of South China,Hengyang 421001,Hunan,China;Hunan Engineering Laboratory of Building Environment Control Technology,Hengyang 421001,Hunan,China;Suzhou Antway Industrial Intelligent Technology Co.,Ltd.,Suzhou 215000,Jiangsu,China;Hunan Nuclear Sanli Technology Engineering Co.,Ltd..,Hengyang 421001,Hunan,China)
机构地区:[1]南华大学土木工程学院,湖南衡阳421001 [2]建筑环境控制技术湖南省工程实验室,湖南衡阳421001 [3]苏州安特威工业智能科技股份有限公司,江苏苏州215000 [4]湖南核三力技术工程有限公司,湖南衡阳421001
出 处:《建筑节能(中英文)》2024年第7期95-101,120,共8页Building Energy Efficiency
摘 要:在当前“碳达峰”和“碳中和”的全球能源脱碳背景下,优化工程技术并促进能源节约变得尤为重要。主要研究了风冷型多联机冷凝器附加喷雾冷却系统的复合冷却技术性能。基于数值模拟软件(Fluent)分析出复合冷却流场中喷嘴的有效作用域,匹配出最优的复合冷却模型,并通过实验验证高温外环境(>43℃)下,复合冷却技术的收益性效果。得出该技术节能效果显著,可以有效地降低多联机外机功耗,最高可下降10%;部分负荷下复合冷却系统整体的制冷性能系数EER要优于风冷型,同时大大提高制冷季节能效比(SEER),提升了7.7%;使得冷凝器的进风干球温度下降7~9℃,保证机组高温外环境工况下仍能满负荷运行。In the current global decarbonization energy background of“carbon peaking”and“carbon neutrality”,it will become especially important to optimize engineering technology to promote energy conservation.This paper mainly studies the performance of composite cooling technology of air-cooled multi-connected outdoor unit additional spray cooling system.The effective scope of the nozzle in the composite cooling flow field is analyzed based on the numerical simulation software(FLUENT),and then the optimal composite cooling model is matched,and finally the profitability of the composite cooling technology under the high temperature external environment(>43℃)is verified by experiments.It is concluded that this technology has a significant energy-saving effect,which can effectively reduce the power consumption of multi-connection and external units,and the power consumption can be reduced by up to 10%;The overall refrigeration coefficient EER of the composite cooling system under partial load is better than that of the air-cooled type,and the energy efficiency ratio(SEER)of refrigeration season is greatly improved,which is increased by 7.7%;The inlet dry bulb temperature of the condenser drops by 7~9℃to ensure that the unit can still operate at full load under high temperature external environmental conditions.
关 键 词:节能 复合冷却 数值模拟 高温外环境 季节能效比
分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:13.59.234.246