检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:龙雯琪 胡英辉 周灵 朱瑞瑞 刘静怡 刘沛 曾恬静 林海兰 李晨 Long Wenqi;Hu Yinghui;Zhou ling;Zhu Ruirui;Liu Jingyi;Liu pei;Zeng Tianjing;Lin Hailan;Li Chen(State Environmental Protection Key Laboratory of Monitoring for Heavy Metal Pollutants,Hunan Ecological Environment Monitoring Center,Changsha 410014,China;Hunan Xiangtan Ecological Environment Monitoring Center,Xiangtan 411104,China)
机构地区:[1]湖南省生态环境监测中心,国家环境保护重金属污染监测重点实验室,湖南长沙410014 [2]湖南省湘潭生态环境监测中心,湖南湘潭411104
出 处:《山东化工》2024年第14期176-179,185,共5页Shandong Chemical Industry
基 金:国家环境保护重金属污染监测重点实验室开放基金(SKLMHM202216)。
摘 要:采用火焰原子吸收分光光度法(FAAS)测定土壤和沉积物中铜Cu、锌Zn、铅Pb、镍Ni、铬Cr,根据测定结果分析该方法的标准曲线相关系数R、检出限MDL、精密度和正确度(包括准确度和加标回收率)等性能参数。实验结果表明,FAAS分析测定Cu、Zn、Pb、Ni和Cr含量在0~2.5 mg/L范围内线性关系较好。FAAS测定Cu、Zn、Pb、Ni和Cr的方法检出限分别为1,0.3,2,2,1 mg/kg;测定下限分别为4,1.2,8,8,4 mg/kg;FAAS测定Cu、Zn、Pb、Ni和Cr精密度在0.7%~17.2%。FAAS测定土壤和沉积物中Cu、Zn、Pb、Ni和Cr标准样品的总体相对误差范围为-2.7%~1.1%,表现出较高的准确度。FAAS的实际样品加标回收测试中,加标回收率范围为80%~119%,满足标准方法要求。Flame Atomic Absorption Spectrophotometry(FAAS)was used to determine Cu,Zn,Pb,Ni and Cr in soil and sediment,and the performance parameters of the method,such as correlation coefficients of the standard curves,limits of detection,precision and accuracy,were analyzed according to the results.The experimental results showed that the linearity of FAAS analysis for the determination of Cu,Zn,Pb,Ni and Cr content was good in the range of 0 mg/L to 2.5 mg/L.The method detection limits of FAAS for the determination of Cu,Zn,Pb,Ni and Cr were 1,0.3,2,2 and 1 mg/kg,respectively;and the lower limits of determination were 4,1.2,8,8 and 4 mg/kg,respectively;and the precision of Cu,Zn,Pb,Ni and Crmeasoried was in the range of 0.7%~17.2%.The overall relative errors of FAAS for the determination of Cu,Zn,Pb,Ni and Cr standard samples in soil and sediment were in the range of-2.7%~1.1%,which demonstrated a high accuracy.In the astual sample spiking recovery test of FAAS,the spirking recorery rate ranges from 80%to 119%.
关 键 词:火焰原子吸收分光光度法 土壤和沉积物 重金属
分 类 号:X832[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.221.242.128