检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:蒋爱丽 贺蔚 张健[1] 俞晓东[1] 陈胜[1] 徐辉[1] Jiang Aili;He Wei;Zhang Jian;Yu Xiaodong;Chen Sheng;Xu Hui(College of Water Conservancy and Hydropower Engineering,Hohai University,Nanjing 210098,China)
出 处:《水动力学研究与进展(A辑)》2024年第3期313-319,共7页Chinese Journal of Hydrodynamics
基 金:国家自然科学基金(52379061);江苏省自然科学基金(BK20230099);水灾害防御全国重点实验室自主研究项目(5240152C2)。
摘 要:水温是重要的环境影响因子。江水源热泵可利用天然水体制冷或加热,具有广阔的应用前景,需进一步明确其对周边水温的影响,尤其是同排同取工况下江水源热泵系统的水温影响效应研究亟待开展。为此,该文以长江汉口滨江江水源热泵为例,建立了三维水动力和水温数值模型,分析了单个和多个江水源热泵能源站取排水对周边河道水温的影响,并提出了布置原则。研究结果表明:①单个江水源热泵取排水主要影响排水口附近区域水温,且水体温升分布有显著的垂向差异,水深增加,影响程度减小;②多组江水源热泵的水温叠加效应显著;③多组江水源热泵同时排放时,水温叠加效应随设置间距的增大而减弱。Water temperature is an important environmental influence.River water source heat pump can use natural water body for cooling and heating,which has broad application prospects.Its influence on the surrounding water temperature needs to be further clarified.Under the condition of the same row and the same take,the research on the influence effect of water temperature of the river water source heat pump system needs to be carried out urgently.Therefore,taking the Hankou riverside water source heat pump of the Yangtze River as an example,a three-dimensional numerical model of hydrodynamic power and water temperature was established,the influence of single and multiple river water source heat pump energy stations on the water temperature of surrounding rivers was analyzed,and the layout principle was proposed.The results show that:①The heat pump drainage of a single river source mainly affects the water temperature in the area near the drainage outlet.There is a significant vertical difference in the distribution of water temperature rise,and the degree of influence decreases with the increase of water depth.②The water temperature superposition effect of multiple groups of river source heat pumps is significant.③When multiple groups of river water source heat pumps are discharged at the same time,the water temperature superposition effect weakens with the increase of the setting interval.
关 键 词:江水源热泵 同排同取 三维水动力 数值模型 布置原则 水温叠加效应
分 类 号:TV135.1[水利工程—水力学及河流动力学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.142.53.239