声振解耦吸音板隔声屏障在特高压变电站中的应用  

Application of Acoustic Barrier With Sound-vibration-decoupled Noise-absorbing Panels in Ultra-high Voltage Substation

在线阅读下载全文

作  者:鞠晶 宋金海 黄金朋 路文志 岳坤林 JU Jing;SONG Jinhai;HUANG Jinpeng;LU Wenzhi;YUE Kunlin(Engineering Management Branch of State Grid Jibei Electric Power Co.,Ltd.,Beijing 100071,China)

机构地区:[1]国网冀北电力有限公司工程管理分公司,北京100071

出  处:《山东电力高等专科学校学报》2024年第4期24-28,共5页Journal of Shandong Electric Power College

摘  要:将声振解耦吸音板隔声屏障应用到特高压变电站中,以解决特高压变电站噪声源设备厂界噪声不达标的问题。声振解耦吸音板隔声屏障由声振解耦吸音板、振动解耦隔振器等部件组成,是一种装设在设备油箱外侧、散热器内侧的高效降噪装置,具有降噪性能好、不需要改变设备内部结构、通用性强、经济性好等特点。噪声测试结果表明,安装声振解耦吸音板隔声屏障后,设备排放噪声可减少15 dB(A)左右,满足了有关标准的要求。The acoustic barrier with sound-vibration-decoupled noise-absorbing panels is ued in ultra-high voltage substation to address the issue that the factory noise at boundary of noise sources in ultra-high voltage substation does not meet the standard requirements.The acoustic barrier with sound-vibration-decoupled noise-absorbing panels,which is composed of sound-vibration decoupled noise-absorbing panels,vibration-decoupled vibration isolators,and other components,is an efficient noise reduction device.The acoustic barrier is installed on the outside of the equipment oil tank and the inside of the radiator,featuring good noise reduction performance,no need to change the internal structure of the equipment,good versatility and economy.The noise test results show that after the installation of the acoustic barrier with sound-vibration-decoupled noise-absorbing panels,the emission noise is reduced by about 15 dB(A),meeting the requirements of relevant standards.

关 键 词:厂界噪声 声振解耦吸音板 减振 并联电抗器 

分 类 号:TU55[建筑科学—建筑技术科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象