检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:朱光明 陈珣 何洪浩 孙瑞强 谢国鸿 杨奕 王阳光 ZHU Guangming;CHEN Xun;HE Honghao;SUN Ruiqiang;XIE Guohong;YANG Yi;WANG Yangguang(State Grid Hunan Electric Power Company Limited Research Institute,Changsha 410208,China;Hunan Province Key Laboratory of Efficient and Clean Power Generation Technologies,Changsha 410208,China;Xi′an Jiaotong University,Xi′an 710061,China;State Grid Hunan Electric Power Company Limited,Changsha 410004,China)
机构地区:[1]国网湖南省电力有限公司电力科学研究院,湖南长沙410208 [2]高效清洁发电技术湖南省重点实验室,湖南长沙410208 [3]西安交通大学,陕西西安710061 [4]国网湖南省电力有限公司,湖南长沙410004
出 处:《湖南电力》2024年第4期1-10,共10页Hunan Electric Power
基 金:国网湖南省电力有限公司科技项目(5216A5220012)。
摘 要:为实现燃煤发电系统效率和灵活性协同提升,促进火电机组转型,提出采用超临界二氧化碳(S-CO_(2))工质、构建燃煤发电与热泵储电耦合的系统(“源储一体”系统)方案。基于热力学第一、二定律,建立集成系统的设计及变工况计算模型,进而对系统灵活性提升潜力和储—放热过程的能效进行分析。结果表明:在S-CO_(2)燃煤发电系统的基础上集成热泵储电技术,可将机组最小输出功率由30%额定负荷降低至0,极大提升了调峰深度和运行灵活性;当选择75%额定负荷为放热工况时,输出功率可增加额定负荷的23.59%,则集成系统的储—释热等效往返效率为78.64%。对储热参数进行敏感性分析,得到熔盐冷罐温度的最佳取值范围为405~420℃,常压水热罐温度的取值范围为70~75℃。To synergistically enhance the efficiency and flexibility of coal-fired power system,and promote the transformation of thermal power units,a scheme of using supercritical carbon dioxide(S-CO_(2))working fluid to construct a coupling system of coal-fired power generation and pumped thermal electricity storage(“source-storage-integrated”system)is proposed.Based on the first and second laws of thermodynamics,the design and off-design calculation models of the integrated system are developed,and the potential of the flexibility improvement and the energy efficiency of the heat storage-release process are analyzed.The results show that by integrating pumped thermal electricity storage technology on the basis of S-CO_(2) coal-fired power system,the minimum output power of the unit can be reduced from the original 30%rated load to zero,which greatly improves the peak regulation depth and operation flexibility.When 75%rated load is selected as the heat release condition,the output power can be increased by 23.59%of the rated load.In addition,the equivalent round-trip efficiency of the heat storage-release process of the integrated system is 78.64%.The sensitivity analysis of heat storage parameters shows that the optimal value range for the molten salt cold tank temperature is 405~420℃,and the value range for the atmospheric pressure water hot tank temperature is 70~75℃.
分 类 号:TK116[动力工程及工程热物理—热能工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.189.30.7