作 者:胡道奇 周松辉 刘如石[2,3] 童鹏 吴刚强 刘汨 邓金凤 刘昕 龚瑶 伍思蓓 杨邦 白丹 李光 Hu Daoqi;Zhou Songhui;Liu Rushi;Tong Peng;Wu Gangqiang;Liu Mi;Deng Jinfeng;Liu Xin;Gong Yao;Wu Sibei;Yang Bang;Bai Dan;Li Guang(R&D Department,Hunan Kangrun Pharmaceutical Co.,Ltd.,Yueyang 414000,China;Microbiology Department,Medicine School of Hunan Normal University,Changsha 410013,China;Immunodiagnostic Reagents Engineering Research Center of Hunan Province,Yueyang 414000,China;Department of Pharmacy,Medicine School of Yueyang Vocational and Technical College,Yueyang 414000,China)
机构地区:[1]湖南康润药业股份有限公司研发部,岳阳414000 [2]湖南师范大学医学院微生物教研室,长沙410013 [3]免疫试剂湖南省工程研究中心,岳阳414000 [4]岳阳职业技术学院医学院药学教研室,岳阳414000
出 处:《国际生物制品学杂志》2024年第4期212-216,共5页International Journal of Biologicals
基 金:湖南省教育厅科学研究项目(23C1026)。
摘 要:目的研制丙型肝炎病毒核心抗原(HCV core antigen,HCV-cAg)磁微粒化学发光法(chemiluminescence microparticle immunoassay,CMIA)的检测试剂,并初步评价其性能。方法采用2株抗HCV-cAg单克隆抗体(单抗)预先包被磁微粒,另2株抗HCV-cAg单抗用吖啶酯标记,制备双抗体夹心CMIA检测试剂;与ELISA试剂盒同时检测210例干扰物样本、1158例健康人样本、140例HCV-RNA阳性样本和2套血清转换盘样本,鉴定研制试剂的特异性和灵敏度。结果CMIA检测试剂的特异性为99.74%,ELISA试剂盒的特异性为99.57%,2种方法干扰物样本的阴性率均为100%;CMIA检测试剂的灵敏度为77.86%,ELISA试剂盒的灵敏度为62.14%,且CMIA检测试剂检出血清转换盘样本阳性的时间早于ELISA试剂盒。结论成功制备了HCV-cAg CMIA检测试剂,该试剂的特异性好、灵敏度高,适用于HCV的早期筛查和临床辅助诊断。Objective To develop a chemiluminescence microparticle immunoassay(CMIA)detection reagent for hepatitis C virus core antigen(HCV-cAg)and preliminarily evaluate its performance.Methods Two anti-HCV-cAg monoclonal antibodies(Mabs)were pre-coated with magnetic particles,and the other two anti-HCV-cAg Mabs were labeled with acridine ester to prepare a CMIA detection reagent for double-antibody sandwich magnetic particles.Using CMIA and ELISA kit,210 interference samples,1158 normal human samples,140 HCV-RNA positive samples,and 2 sets of serum conversion disk samples were detected simultaneously to identify the specificity and sensitivity of the developed reagent.Results The specificity of CMIA detection reagent was 99.74%,and the specificity of ELISA kit was 99.57%.The negative rates of both methods for detecting interference samples were 100%.The sensitivity of CMIA detection reagent was 77.86%,the sensitivity of ELISA kit was 62.14%,and the CMIA detection reagent detected positive serum conversion disk samples earlier than ELISA kit.Conclusion HCV-cAg CMIA detection reagent is successfully prepared with good specificity and high sensitivity,and is suitable for early screening and clinical auxiliary diagnosis of HCV.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.145.36.157