在线阅读下载全文

作  者:李忠思 陶祥生 兰思东[2] 储少军[2] LI Zhongsi;TAO Xiangsheng;LAN Sidong;CHU Shaojun(Wuxi Beike Automation Technology Co.,Ltd.,Jiangsu Wuxi 214000,China;School of Metallurgical and Ecological Engineering,University of Science and Technology Beijing,Beijing 100083,China)

机构地区:[1]无锡北科自动化科技有限公司,江苏无锡214000 [2]北京科技大学冶金与生态工程学院,北京100083

出  处:《铁合金》2024年第4期1-5,共5页Ferro-alloys

摘  要:本文针对矿热炉低压补偿技术在铁合金行业应用中涉及的无功补偿量计算方法、矿热炉短网无功功率占比和大电流导体集肤效应进行了理论分析,同时针对矿热炉谐波治理问题,提出根据谐波检测结果判定是否需要治理和设计必需的滤波装置。最后提出了矿热炉低压补偿设计的基本原则。The calculation method of reactive power compensation,the reactive power ratio in short network,and the skin effect of high current conductor in the application of low-voltage compensation technology in ferroalloy industry were analyzed theoretically in this paper.In view of the harmonic management,it is proposed that we should determine whether it is necessary to control and design the necessary filter device according to the test results.Finally,the basic design principle of low-voltage compensation of the submerged arc furnace is proposed.

关 键 词:矿热炉 低压补偿 谐波治理 有功功率 无功功率 

分 类 号:TF332[冶金工程—冶金机械及自动化]

 