原子荧光法测汞影响因素的探讨  

Exploration of Factors Affecting Mercury Measurement by Atomic Fluorescence Method

在线阅读下载全文

作  者:郑金龙 Zheng Jinlong(Guang'an Ecological Environment Monitoring Center Station,Guang'an Sichuan 638000,China)

机构地区:[1]四川省广安生态环境监测中心站,四川广安638000

出  处:《山西化工》2024年第8期83-84,87,共3页Shanxi Chemical Industry

摘  要:原子荧光法与其他方法测汞相比,具有检出限更低、抗干扰力更强、操作方便等优点。本文分别从仪器条件、仪器本身、试剂、玻璃器皿和实验环境等因素阐述原子荧光法测汞的影响和干扰,分析其存在的原因,提出合理的改进措施。Compared with other methods for measuring mercury,atomic fluorescence method has the advantages of lower detection limit,stronger anti-interference ability,and convenient operation.This article elaborates on the influence and interference of atomic fluorescence method for mercury measurement from factors such as instrument conditions,instrument itself,reagents,glassware,and experimental environment,analyzes the reasons for its existence,and proposes reasonable improvement measures.

关 键 词: 测定 原子荧光 影响因素 

分 类 号:X832[环境科学与工程—环境工程] O657.31[理学—分析化学]

 