摘  要:针对钢结构表面及其支撑结构在某环境水溶液中的腐蚀情况,开展了低合金钢在模拟水溶液的缝隙腐蚀实验、浸泡实验及电化学实验等研究,分析了低合金钢无缝试样与缝隙试样在模拟水溶液中的腐蚀形貌、腐蚀产物成分、电化学参数等。研究结果表明,低合金钢在模拟水溶液中的腐蚀以电化学反应为主,锈层腐蚀初期产物为Fe(OH)3、FeOOH类产物,中后期产物为铁的无定型氧化物Fe3O4,且缝隙试样腐蚀弱于无缝试样,缝隙内腐蚀远远弱于缝隙外腐蚀。因此,低合金钢在模拟水溶液中对缝隙腐蚀不敏感。In view of the corrosion of steel strusture surface and its supporting strusture in an ambient water solution,the crack corrosion experiment,soaking experiment and electrochemical experiment of low alloy steel have been studied in the simulated aqueous solution.The corrosion morphology,corrosion product composition and electrochemical parameters of low alloy steel seamlss sample and crack sample in simulated aqueous solution have been analyzed.The results show that the corrosion of low alloy steel is mainly electrochemical reaction in the simulated aqueous solution.The initial corrosion products of rust layer are Fe(OH)3 and FeOOH products while the corrosion products in middle and later period are Fe3O4.The corrosion of crack sample is weaker than that of seamless sample,and the corrosion in the crack is much weaker than the corrosion outside the crack.Therefore,low alloy steel is not sensitive to crack corrosion in the simulated aqueous solution.

关 键 词:水溶液 低合金钢 缝隙腐蚀 

分 类 号:TQ630[化学工程—精细化工]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象