检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张松 李少群 张方[1] 黄健 郭虎 王燕兰[1] 韩瑞山 卢飞朋 ZHANG Song;LI Shao-qun;ZHANG Fang;HUANG Jian;GUO Hu;WANG Yan-lan;HAN Rui-shan;LU Fei-peng(State Key Laboratory of Transicent Chemical Effects and Control,Shaanxi Applied Physics and Chemistry Research Institute,Xi’an,710061;College of Machinery,Dalian University of Technology,Dalian,116081;School of Chemistry and Chemical Engineering,Nanjing University of Science and Technology,Nanjing,210094)
机构地区:[1]陕西应用物理化学研究所瞬态化学效应与控制全国重点实验室,陕西西安710061 [2]大连理工大学机械工程学院,辽宁大连116081 [3]南京理工大学化学与化工学院,江苏南京210094
出 处:《火工品》2024年第4期74-79,共6页Initiators & Pyrotechnics
基 金:中国博士后科学基金资助(No.2023M733283)。
摘 要:为了实时掌握微纳米火工药剂制备过程的安全性及产品质量的稳定性,以典型传爆药六硝基茋(HNS)为研究对象,基于微流控、温度传感、压力传感及近红外测试技术设计微流控在线监测系统,对微纳米HNS制备过程进行在线监测研究。结果表明:制备过程中,两相流体的混合是一个放热过程,流体温度由19.4℃升高至23.6℃,且其在通道中充分混合需要一定的停留时间;过长的混合时间和通道内温度分布不均等因素会导致最终产品的粒径变大且分布较宽;微流体注射泵达到稳定工作至少需5 min左右,微通道内的最大压力可达0.15 MPa左右;通过近红外光谱的特征峰位置与吸光度强度,可以判断连续制备过程中流体参数及产品粒度分布的稳定性。In order to real-time grasp the safety of the preparation process of pyrotechnic agents based on microfluidic technology and the stability of product quality,taking the typical booster explosive hexanitroaniline(HNS)as the research object,a microfluidic online monitoring system based on microfluidic,temperature sensing,pressure sensing and near-infrared testing technology was designed to conduct online monitoring research on the preparation process of micro-nano HNS.The results show that during the preparation process,the mixing of two-phase fluid is an exothermic process,with the fluid temperature increasing from 19.4℃to 23.6℃,and it requires a certain residence time to achieve complete mixing in the channel;Excessive mixing time and uneven temperature distribution in the channel can lead to an increase in the particle size and wider distribution of the final products;The stable operation of the microfluidic injection pump takes at least 5 minutes,and the maximum pressure inside the microchannel can reach about 0.15 MPa;The stability of fluid parameters and product particle size distribution during continuous preparation can be determined by the characteristic peak positions and absorbance intensity of near-infrared spectroscopy.
分 类 号:TJ450.6[兵器科学与技术—火炮、自动武器与弹药工程] TQ560.7[化学工程—炸药化工]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49