检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:招展奇 杨琳 代萌 葛慧青[4] 谢国喜 解立新[5] 郑劲平[6] Zhao Zhanqi;Yang Lin;Dai Meng;Ge Huiqing;Xie Guoxi;Xie Lixin;Zheng Jinping(School of Biomedical Engineering,Guangzhou Medical University,Guangzhou 511436,China;Department of Aerospace Medicine,Air Force Medical University,Xi′an 710032,China;Department of Biomedical Engineering,Air Force Medical University,Xi′an 710032,China;Department of Respiratory Care,Sir Run Run Shaw Hospital,Zhejiang University School of Medicine,Regional Medical Center for National Institute of Respiratory Diseases,Hangzhou 310016,China;College of Respiratory and Critical Care Medicine,Chinese PLA General Hospital,Beijing 100091,China;Department of Respiratory and Critical Care Medicine,the First Affiliated Hospital of Guangzhou Medical University,Guangzhou 510120,China)
机构地区:[1]广州医科大学生物医学工程学院,广州511436 [2]空军军医大学航空航天医学系,西安710032 [3]空军军医大学军事生物医学工程学系,西安710032 [4]浙江大学医学院附属邵逸夫医院呼吸治疗科国家呼吸区域医疗中心,杭州310016 [5]解放军总医院呼吸与危重症医学部,北京100091 [6]广州医科大学附属第一医院呼吸与危重症医学科,广州510120
出 处:《国际呼吸杂志》2024年第8期869-876,共8页International Journal of Respiration
基 金:国家自然科学基金(82070087、52077216、52277235);广东省普通高校创新团队项目(2023KCXTD026);广州国家实验室研发项目(SRPG22-018)。
摘 要:基于电阻抗断层成像技术的区域肺功能评估,具有床旁、简便、无创、无辐射等优势,能提供全新的实时局部肺功能信息。该技术由国外研究者提出,应用在肺功能筛查、术前检查、呼吸康复等相关临床研究。该技术规范经本团队前期临床研究实践论证,综合相关文献,并经过本领域临床专家和生物医学工程学专家讨论达成,内容包括适应证与禁忌证、技术方法实施、数据分析和解读等方面,旨在统一和规范使用电阻抗断层成像技术检测区域肺功能的临床流程,提高其有效性,实现对结果的统一解读。Regional lung function assessment based on electrical impedance tomography(EIT)provides novel real-time regional functional information with multiple advantages,such as bedside examination,convenience,non-invasiveness,and radiation-free.This technology was initially proposed by foreign researchers and applied in clinical research about lung function screening,preoperative examination,respiratory rehabilitation,etc.The technical specification for regional lung function assessment based on EIT is based on the previous clinical research and practice in our centers,literature review,and discussions among clinical and biomedical engineering experts in this field.It consists of indications and contraindications,implementation of technical methods,data analysis and interpretation.The technical specification is designed to facilitate the unified and standardized use of EIT for regional lung function assessment,improve its effectiveness,and achieve a unified interpretation of the results.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30