300 MW机组引风机电机振动故障诊断及动平衡试验  

Vibration Fault Diagnosis and Dynamic Balancing Test for the Induced Draft Fan Motor of a 300 MW Unit

在线阅读下载全文

作  者:汤杰杰 徐天宇 徐鹏程 TANG Jiejie;XU Tianyu;XU Pengcheng(State Grid Anhui Electric Power Co.,Ltd.Electric Power Research Institute,Hefei 230601,China)

机构地区:[1]国网安徽省电力有限公司电力科学研究院,安徽合肥230601

出  处:《安徽电气工程职业技术学院学报》2024年第3期75-79,共5页Journal of Anhui Electrical Engineering Professional Technique College

摘  要:针对某300 MW机组引风机电机振动超标故障,对电机及引风机进行全面振动测试和分析,明确了引风机电机振动故障的原因,通过在电机风扇和电机与引风机的联轴器上加重,消除了电机振动故障,满足了设备的安全稳定运行需要,同时在两个加重面上加重的影响系数可为同类型转子动平衡试验提供经验。In response to the vibration fault of the induced draft fan motor in a 300 MW unit,a comprehensive vibration test and analysis were conducted on both the motor and the induced draft fan,and the causes were clearly identified.By adding weight to the motor fan and the coupling between the motor and the induced draft fan,the motor vibration fault was eliminated,satisfying the need of safe and stable operation of the equipment.Meanwhile,the influence coefficients obtained from adding weights on two surfaces can provide experience for similar rotor dynamic balance tests.

关 键 词:300 MW机组 引风机电机 振动 故障诊断 