检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张泽宇 曾立静 王月栋 侯兆新[1,3] 刘学春 张爱林[2] 李伟男[4] ZHANG Zeyu;ZENG Lijing;WANG Yuedong;HOU Zhaoxin;LIU Xuechun;ZHANG Ailin;LI Weinan(Central Research Institute of Building and Construction Co.,Ltd.,MCC Group,Beijing 100088,China;Beijing Engineering Research Center of High-Rise and Large-Span Prestressed Steel Structures,Beijing University of Technology,Beijing 100124,China;National Steel Structure Engineering Technology Research Center,Beijing 100088,China;Steel Structure Branch,China Jingye Engineering Technology Co.,Ltd.,Beijing 100088,China)
机构地区:[1]中冶建筑研究总院有限公司,北京100088 [2]北京工业大学,北京市高层和大跨度预应力钢结构工程技术研究中心,北京100124 [3]国家钢结构工程技术研究中心,北京100088 [4]中国京冶工程技术有限公司钢结构公司,北京100088
出 处:《工业建筑》2024年第8期62-69,共8页Industrial Construction
基 金:济宁市重点研发计划“全球揭榜”项目(2022JBZP004);住房和城乡建设部科学技术计划项目(2022-K-145)。
摘 要:对装配式Z形钢结构梁柱连接节点进行了单调和往复循环加载试验及有限元分析,以研究其力学性能。对不同连接强度设计下的Z形节点,分别进行了转动刚度、破坏模式、承载能力、滞回性能、耗能能力和刚度退化等研究。结果表明:装配式Z形钢结构梁柱连接节点具有良好的延性且能够做到塑性铰外移。节点连接强度可显著影响其滞回性能和塑性抗弯能力;较低的强度设计系数(0.2~0.9)使节点破坏模式为螺栓率先发生破坏,其滑移失效承载力和极限承载力与强度设计系数基本呈线性正相关,且节点转动性能表现为半刚性;节点强度设计系数较高时(0.9~1.3),其滑移失效承载力和极限承载力基本保持不变,节点破坏模式转变为构件率先发生破坏,节点抗弯性能表现为刚性连接。此外,该节点构造形式下所需螺栓数量少,安装高效且经济性强,具有一定的工程应用价值。The experiments under monotonic and cyclic loading conditions and simulation were conducted to investigate the mechanical properties of prefabricated Z-shaped steel beam-to-column connections.The rotational stiffness,failure mode,bearing capacity,hysteretic performance,energy dissipation,and stiffness degradation of Z-shaped connections with different designed strengths were studied respectively.The results showed that the prefabricated Z-shaped steel beam-to-column connections showed good ductility and could achieve plastic hinge movement outside the panel zone.The designed strength showed a significant effect on the hysteretic performance and plastic bending resistance of Z-shaped connections.The small value of designed strength parameter(0.2-0.9)made that the failure mode of Z-shaped connections was premature damage of bolts.The anti-slip and ultimate bearing capacity of Z-shaped connections increased linearly with the increase of designed strength,and the rotational performance of Z-shaped connections was semi-rigid.In case of the large value of designed strength parameter(0.9-1.3),anti-slip and ultimate bearing capacity of Z-shaped connections were almost unchanged.The failure mode was changed to premature damage of connected members,and the rotational performance of Z-shaped connections was rigid.In addition,the number of bolts required by the proposed Z-shaped connections was relatively small,and the installation was efficient and economical,
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.221.70.17