检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:谢智宇 林涛 杨光辉 王云端 林小嘉 陈海焱[1] 林龙沅[1] XIE Zhiyu;LIN Tao;YANG Guanghui;WANG Yunduan;LIN Xiaojia;CHEN Hanyan;LIN Longyuan(School of Environment and Resources,Southwest University of Science and Technology,Mianyang 621000,China;Department of Nuclear Engineering and Technology,Guangyuan China Nuclear Vocational and Technical College,Guangyuan 628003,China)
机构地区:[1]西南科技大学环境与资源学院,四川绵阳621000 [2]广元中核职业技术学院核工程与技术系,四川广元628003
出 处:《中国粉体技术》2024年第5期146-157,共12页China Powder Science and Technology
基 金:国家自然科学基金项目,编号:52204286;四川省科技计划资助项目,编号:2023YFS0362。
摘 要:【目的】为优化卧式三角型滤筒除尘器的清灰性能,探究不同喷吹气流对滤筒内部压力分布的影响,获得不同喷吹孔型式对三角型滤筒的清灰性能的影响规律。【方法】分别采用直管喷吹孔、文氏里管、散射喷嘴、新型曲面诱导引射器共4种喷吹孔型式的诱导引流装置对卧式三角型滤筒开展冷态脉冲实验,以侧壁压强峰值和相对标准偏差作为评价清灰性能的技术指标,分别探讨不同条件下的喷吹射流对滤筒内壁压力分布的影响。【结果】在喷吹压强分别设为0.3、0.4、0.5 MPa的条件下,采用直管、文丘里管、新型曲面诱导引射器时喷吹距离分别设为150、200、250、300、350、400 mm,采用散射喷嘴时喷吹距离分别设为25、50、75、100、125、150、175 mm,则采用直管、文丘里管、散射喷嘴、新型曲面诱导引射器时的平均侧壁压强峰值分别为1037、1758、952、1533 Pa,相对标准偏差分别为0.76、0.58、0.09、0.16;采用新型曲面诱导引射器喷吹孔时,比采用散射喷嘴时的清灰强度高61%,比采用文丘里管时的相对标准偏差小0.47。【结论】新型曲面诱导引射器同时兼顾对侧壁压强峰值和相对标准偏差的要求,在4种喷吹孔型式中清灰性能最佳。Objective In order to enhance the dust removal performance of the horizontal triangular filter cartridge dust collector,this study investigates the influence of pulse jet blowing generated by various nozzle configurations within the induction drafting apparatus on the pressure distribution across the interior surface of the horizontal triangular filter cartridge.This approach facilitates the identification of the key rules governing the effectiveness of different nozzle designs in dust removal.Methods Different induction draft devices equipped with four types of nozzles—straight pipe nozzle,Venturi tube nozzle,scattering nozzle,and a new curved surface induction ejector—were employed to conduct cold-state pulse jet tests on horizontal triangular filter cartridge.During these tests,peak sidewall pressures at various measurement points were recorded.The relative standard deviation of these pressures was then calculated and analyzed.The two parameters were used to characterize the intensity and uniformity of the cleaning pressure,serving as technical indicators of cleaning performance.The effects of different experimental parameters on the pressure distribution on the inner walls of the filter cartridges induced by the pulse jet streams,were also investigated.Results and Discussion With the straight pipe nozzle,when the spray pressure was 0.3,0.4,or 0.5 MPa and the spraying distance ranged from 150 to 400 mm,the average sidewall pressure peaks at measuring points P1 and P2 on the left side of the filter cylinder were all below the effective cleaning pressure threshold.The average relative standard deviation of 0.76 indicated poor performance in both cleaning strength and uniformity.When Venturi tube nozzle was used at spray pressures of 0.3,0.4 or 0.5 MPa while the spraying distance was≥300 mm,the average sidewall pressure peaks at all measuring points met the effective cleaning pressure threshold,with an average relative standard deviation of 0.58,indicating poorer cleaning uniformity.This configuration is su
分 类 号:X964[环境科学与工程—安全科学] TB4[一般工业技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49