作 者:杨康 Yang Kang
出 处:《城市建筑》2024年第18期215-218,共4页Urbanism and Architecture
摘 要:为保障建筑设计中自动喷水灭火系统联动控制系统的合理性、可靠性,文章从电气专业的角度分析解读自动喷水灭火系统中的五种常见的系统形式。对不同系统的结构形式、设备组成及运行原理进行了比照研究,并对各系统的控制要求、受控部位及信号处理进行了综合的分析,不同自动喷水灭火系统的联动控制有很大的差异,电气设计须对不同的自喷系统做出针对性的联动控制设计。To ensure the rationality and reliability of the linkage control system in sprinkler system of the architectural design,the paper analyzes and interprets five common forms of sprinkler system from the perspective of electrical engineering.A comparative study was conducted on the structural forms,equipment composition,and operating principles of different sprinkler systems,and a comprehensive analysis was conducted on the control requirements,controlled parts,and signal processing of each system.The linkage control of different sprinkler systems varies greatly,and the electrical design needs to make targeted linkage control designs for different sprinkler systems.