How to achieve energy efficiency in buildings without compromising indoor air quality:A case study on enthalpy exchangers  

在线阅读下载全文

作  者:LI Hao ZHANG Tao LIU XiaoHua 

机构地区:[1]Department of Building Science,Tsinghua University,Beijing 100084,China

出  处:《Science China(Technological Sciences)》2024年第9期2648-2658,共11页中国科学(技术科学英文版)

基  金:supported by the National Key Research and Development Program of China(Grant Nos.2023YFC3807001 and 2023YFC3807101);the National Natural Science Foundation of China(Grant Nos.52394223 and 52278114);Tsinghua University-Architectural Design and Research Institute Joint Research Center for Synergy and Wisdom Creation of Architecture。

摘  要:As a representative heat recovery device,the fixed-plate enthalpy exchanger possesses the advantages of high recovery effectiveness,low pressure drop,and small space occupied.Still,indoor contaminants may transfer to fresh air through the enthalpy exchanger simultaneously,causing cross-contamination risk.However,the cross-contamination risk of the fixed-plate enthalpy exchanger has been under-researched in previous studies.As a result,this study experimentally investigates the energy performance,formaldehyde and ammonia transfer rates of paper-based and membrane-based enthalpy exchangers.The results illustrate that the enthalpy recovery effectiveness of the plate exchangers ranges from 60%–85%.The formaldehyde transfer rate through the exchangers varies from 5%–23%,and the ammonia transfer rate is 0–15%.The high effectiveness and low contaminant transfer rates are conducive to the promising application of the fixed-plate enthalpy exchangers.In addition,the energy reclaimed increases with the increase of the absolute indoor-outdoor enthalpy difference.The formaldehyde and ammonia transfer rates and cross-contamination risk slightly decrease with increasing temperature but significantly increase with increasing humidity.Moreover,the experimental results demonstrate that the contaminant transfer rates through the membranebased exchanger are lower than those of the paper-based exchanger.This study provides a reference for the fixed-plate enthalpy exchanger design in practical applications.

关 键 词:building energy efficiency enthalpy recovery heat recovery effectiveness CROSS-CONTAMINATION 

分 类 号:TU834[建筑科学—供热、供燃气、通风及空调工程] TU201.5

 