作 者:孙湛钧 SUN Zhanjun(Shuyu Civilian Pharmacy Chain Co.,Ltd.,Jinan 250000,China)
机构地区:[1]漱玉平民大药房连锁股份有限公司,山东济南250000
出 处:《中国高新科技》2024年第16期67-69,共3页
摘 要:文章针对锻造炉周边风场对厂区建筑群自然热压通风的影响效果展开研究。设定建筑周边风场参数条件后,以划分建筑通风气流模式为基础,设定风场强度与建筑通风量对应关系;构建热压计算模型,利用该模型获取建筑群自然通风量。实验结果表明,厂区建筑群周边风场的风压受多种因素影响,在室内热源强度的影响条件下,建筑贯流通风模式相比单侧通风模式和浮力通风模式,产生的自然热压通风量更高。In this paper,the effect of the wind field around the forging furnace on the natural hot pressure ventilation of the factory buildings is studied.Firstly,after setting the parameters of the wind field around the building,the corresponding relationship between the wind field intensity and the building ventilation volume is set based on the division of the building ventilation flow mode.Then,the calculation model of hot pressing is constructed,and the natural ventilation volume is obtained by this model.Finally,the experimental results show that the wind pressure of the surrounding wind field of the plant complex is affected by many factors.Under the influence of indoor heat source intensity,the natural hot pressure ventilation of the building.
关 键 词:锻造炉 周边风场 建筑群 自然热压通风 气流模式
分 类 号:TU834[建筑科学—供热、供燃气、通风及空调工程]