作 者:陈振宇 杨宝坤 姜婷 徐伟[1] CHEN Zhen-yu;YANG Bao-kun;JIANG Ting;XU Wei(School of Medical Technology,Beijing Institute of Technology,Beijing 100081,China)
出 处:《质谱学报》2024年第5期609-615,共7页Journal of Chinese Mass Spectrometry Society
基 金:北京市自然科学基金——海淀原始创新联合基金(L222150);中国中医科学院科技创新工程课题(CI2023C035YGL);北京理工大学青年学术启动计划(XSQD-6120230051)。
摘 要:原位实时监测可挥发性有机物(VOCs)对环境和人体健康至关重要,便携式质谱仪正在发展成为一种用于现场快速分析VOCs的新工具。本研究研制了一种基于非连续进样接口的便携式质谱仪,并结合了亚真空等离子体电离源。该便携质谱仪配备线性离子阱质量分析器,总质量约4.6 kg,尺寸217 mm×162 mm×106 mm,总功率不超过150 W。进样接口选用全金属电磁阀门作为大气压限流核心部件,避免了传统夹管阀需要使用橡胶等材质软管的缺陷,从而提升了进样装置的重复性和环境适应性。经过系统性的优化,仪器分辨率可达0.2 u(半峰宽),萘的分析灵敏度可达343μg/m^(3)。Due to their high reactivity,volatile organic compounds(VOCs)can engage in physical and chemical reactions with particulate matter in the atmosphere,leading to air pollution.Extended exposure to VOCs may result in various health concerns,including respiratory system problems,neurological effects,skin and eye irritation,and an increased risk of certain cancers.Traditional benchtop mass spectrometers possess the advantages of high sensitivity and rapid analysis capabilities,but the large size typically confines their applications to professional laboratories.To overcome this limitation,portable mass spectrometers are emerging as a new tool for in-situ analysis.In this study,a portable mass spectrometer based on discontinuous atmosphere pressure interface was developed,which combined with a sub-vacuum plasma ionization source.Ion trap,known for its small size and adequate performance,was adopted in this miniaturized mass spectrometer.This portable mass spectrometer features a total weight of about 4.6 kg,with the dimensions of 217 mm×162 mm×106 mm,and operates with a power consumption under 150 W.On this design,a fully metallic solenoid valve was selected as the core component to limit atmospheric pressure,eliminating the need for the rubber tubing used in traditional pinch valves.Compared to traditional pinch valves,this solenoid valve ensures a more stable airflow during experiments.As a result,the repeatability and environmental adaptability of the portable mass spectrometer were improved.A certain delay marked as radio freqency(RF)delay was introduced between the injection and cooling periods,and the RF-delay time was optimized.Frequency scanning mode and amplitude scanning mode were tested in parallel.Despite of a trade-off in size,amplitude scanning offered improved resolution,enabling the differentiation of ions with close mass to charge ratios.After systematic optimization,satisfactory performances in mass resolution and sensitivity were achieved.The mass resolution of the mass spectrometer for dimethyl ca
关 键 词:便携质谱仪 离子阱 非连续进样 可挥发性有机物(VOCs)
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49