Quieting the neonatal intensive care unit:A quality improvement initiative  

在线阅读下载全文

作  者:Darshan Rajatadri Rangaswamy Niranjan Kamble Amulya Veeramachaneni 

机构地区:[1]Department of Pediatrics,Subbaiah Institute of Medical Sciences,Shimoga 577222,Karnataka,India

出  处:《World Journal of Clinical Pediatrics》2024年第3期53-60,共8页世界临床儿科杂志

摘  要:BACKGROUND The neonatal intensive care unit(NICU)is vital for preterm infants but is often plagued by harmful noise levels.Excessive noise,ranging from medical equipment to conversations,poses significant health risks,including hearing impairment and neurodevelopmental issues.The American Academy of Pediatrics recommends strict sound limits to safeguard neonatal well-being.Strategies such as education,environmental modifications,and quiet hours have shown to reduce noise levels.However,up to 60%of the noises remain avoidable.High noise exposure exacerbates physiological disturbances,impacting vital functions and long-term neurological outcomes.Effective noise reduction in the NICU is crucial for promoting optimal neonatal development.AIM To measure the sound levels in a NICU and reduce ambient sound levels by at least 10%from baseline.METHODS A quasi-experimental quality improvement project was conducted over 4 mo in a 20-bed level 3 NICU in a tertiary care medical college.Baseline noise levels were recorded continuously using a sound level meter.The interventions included targeted education,environmental modifications,and organizational changes,and were implemented through three rapid Plan-Do-Study-Act(PDSA)cycles.Weekly feedback and monitoring were conducted,and statistical process control charts were used for analysis.The mean noise values were compared using the paired t-test.RESULTS The baseline mean ambient noise level in the NICU was 67.8 dB,which decreased to 50.5 dB after the first cycle,and further decreased to 47.4 dB and 51.2 dB after subsequent cycles.The reduction in noise levels was 21%during the day and 28%PDSA cycle(mean difference of−17.3 dB,P<0.01).Peak noise levels decreased from 110 dB to 88.24 dB after the intervention.CONCLUSION A multifaceted intervention strategy reduced noise in the NICU by 25%over 4 months.The success of this initiative emphasizes the significance of comprehensive interventions for noise reduction.

关 键 词:Quality improvement Noise pollution Preterm care Sound measurement Plan-Do-Study-Act 

分 类 号:R722.1[医药卫生—儿科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象