某高海拔地区水电站地下厂房布置与设计  被引量:1

在线阅读下载全文

作  者:吴银刚 孔宇田 杨东 龙益彬 孙志军 

机构地区:[1]中国电建集团贵阳勘测设计研究院有限公司,贵阳550081

出  处:《科技创新与应用》2024年第28期131-134,共4页Technology Innovation and Application

摘  要:该工程为地下厂房,地处某西部高海拔区域,场地地震基本烈度为Ⅷ度。结合地质条件等对厂区各建筑枢纽进行合理布置,根据机电设备布置需要及业主公司内部企业规范要求,对厂房各部位进行合理布置及优化设计。该地下厂房经多次审查论证表明,其布置满足结构安全和功能需求,厂区结构布置紧凑、合理,供其他类似工程参考。The project is an underground factory building located in a high altitude area in the west.The basic earthquake intensity of the site is VIII.Various building hubs in the factory were reasonably arranged based on geological conditions,etc.,and various parts of the factory were reasonably arranged and optimized according to the layout needs of electromechanical equipment and the internal enterprise specifications of the owner company.After many reviews and demonstrations,the underground powerhouse has shown that its layout meets the structural safety and functional requirements,and the structural layout of the plant area is compact and reasonable,which can be used as a reference for other similar projects.

关 键 词:高海拔 水电站 地下厂房 布置设计 结构安全 功能需求 

分 类 号:TV731[水利工程—水利水电工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象