镍钛支架在不同模拟液中镍离子析出量的检测方法  

Study on the detection method of nickel ion precipitation in Ni-Ti scaffolds in different simulated liquids

在线阅读下载全文

作  者:张笑旻[1] 陈永康[1] 王帅 刘莉[1] Zhang Xiaomin;Chen Yongkang;Wang Shuai;Liu Li(Shanghai Institute of Measurement and Testing Technology)

机构地区:[1]上海市计量测试技术研究院

出  处:《上海计量测试》2024年第4期43-45,共3页Shanghai Measurement and Testing

摘  要:阐述了镍钛支架镍离子析出测试方法的研究过程,通过使用电感耦合等离子体质谱仪对镍钛支架的镍离子析出行为进行了分析与评估。研究包括样品的制备、试剂的选择、仪器的优化、标准品的制备以及质控溶液的制备等多个方面,旨在建立一种准确、可靠且实用的镍离子析出测试方法。In this paper,the research process of nickel ion precipitation testing method of nickel-titanium stent was described in detail.The nickel ion precipitation behavior of nickel-titanium stent was analyzed and evaluated comprehensively by using inductively coupled plasma spectrometer(ICP).The research includes sample preparation,reagent selection,instrument optimization,standard preparation and quality control solution preparation,aiming to establish an accurate,reliable and practical nickel ion precipitation test method.

关 键 词:镍钛支架 镍离子析出 测试方法 准确度 精密度 

分 类 号:O657.63[理学—分析化学] TH77[理学—化学]

 