垂直轴偏差测量仪的量值溯源  

Measurement traceability of vertical axis deviation measuring instrument

在线阅读下载全文

作  者:何灵芝 王景凡 毛斌 王毅 罗杰 He Lingzhi;Wang Jingfan;Mao Bin;Wang Yi;Luo Jie(Shaanxi Institute of Metrology Science)

机构地区:[1]陕西省计量科学研究院

出  处:《上海计量测试》2024年第4期46-48,52,共4页Shanghai Measurement and Testing

摘  要:为了解决垂直轴偏差测量仪的有效溯源,确保瓶容器的垂直轴偏差满足企业生产需求,根据垂直轴偏差测量仪的测量原理,对垂直轴偏差测量仪的校准项目及校准方法进行了研究,并对该仪器垂直轴偏差的校准结果进行不确定度评定。结果表明:校准结果不确定度小于允许误差的三分之一要求。由此可见,此校准方法准确可靠。In order to solve the effective traceability of the vertical axis deviation measuring instrument and ensure that the vertical axis deviation of the bottle container meets the production needs of the enterprise,according to the measurement principle of the vertical axis deviation measuring instrument,the calibration items and calibration methods of the vertical axis deviation measuring instrument are studied in this paper,and the uncertainty of the calibration results of the vertical axis deviation of the instrument is evaluated.The results show that the uncertainty of the calibration results is less than one-third of the allowable error requirement.This shows that this calibration method is accurate and reliable.

关 键 词:垂直轴偏差测量仪 垂直轴偏差 圆跳动 指示表 量值溯源 不确定度 

分 类 号:TH71[机械工程—测试计量技术及仪器]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象