摘  要:外墙保温与结构一体化设计中,如何做好外墙接缝处的节点设计是确保外墙质量的关键。论文介绍了预制混凝土夹心保温外墙、预制混凝土硅墨烯反打保温外墙和现浇混凝土硅墨烯免拆保温模板外墙3种外墙系统,提出了3种外墙系统在竖向和水平交接位置的节点设计方法。The key to ensure the quality of external walls is to design the joint of external wall.This paper introduces three kinds of exterior wall systems,includingprefabricated concrete sandwich insulation exterior wall,precast concrete siligraphene anti-insulation exterior wall and cast-in-place concrete siligraphene non-demolition insulation formwork exterior wall,and puts forward the joint design methods of the three exteriorwall systemsin vertical andhorizontal junction positions.

关 键 词:装配式建筑 外墙保温系统 预制外墙 交接处理 