电感耦合等离子体发射光谱法测定锅炉及换热器中工业垢样钙、镁、铁含量  

The Content of Industrial Sale Calcium Magnesium and Iron in Doilers and Heat Exchanger was Determined by Inductively Coupled Plasma Emission Spectroscopy

在线阅读下载全文

作  者:原雯[1] 李军[2] Yuan Wen;Li Jun(Research Institute of Urumqi Petrochemical Company,Xinjiang Uygur Autonomous Region Urumqi,830019,China;Boiler Workshop of Thermal Power Department of Urumqi Petrochemical Company,Xinjiang Uygur Autonomous Region Urumqi,830019,China)

机构地区:[1]乌鲁木齐石化公司研究院,新疆维吾尔自治区乌鲁木齐830019 [2]乌鲁木齐石化公司热电部锅炉车间,新疆维吾尔自治区乌鲁木齐830019

出  处:《实验与分析》2024年第3期73-76,共4页LABOR PRAXIS

摘  要:本文建立一种灼烧酸化样品后利用电感耦合等离子发射光谱法测定锅炉及换热器中的钙、镁、铁金属含量的分析方法。探讨了样品预处理条件,并用盐酸、硝酸及氢氟酸做为酸性介质。该方法对钙、镁、铁的加标回收率符合分析要求,测定的相对标准偏差不超过3.5%,可用于垢样中钙、镁、铁金属含量的测定。This article establishes an analytical method for the metal cotents of calcium,magnesium and iron by inductively coupled plasma emission spectrometry after burning and acidifying samples in boilers and heat exchangers.The sample pretreatment conditions were discussed.Using hydrochloric acid,nitric acid and hydrofluoric acid as acidic media,The recovery rates of calcium,magnesium,and iron in this method meet the requirements of analytical analysis,with a relative standard deviation of no more than 3.5%.It can be used for the determination of calcium,magnesium,and iron metal content in scale samples.

关 键 词:垢样 电感耦合等离子体发射光谱 钙、镁、铁 灼烧酸化 

分 类 号:T[一般工业技术]

 