摘  要:某电厂660MW超超临界锅炉通过168小时试运后,出现了机组在低负荷运行时再热汽温偏低的问题,对锅炉低负荷下的运行经济性带来较大的影响。本文主要分析造成机组低负荷运行再热汽温偏低的原因,并给出再热器调整改造的方案。After the 660MW ultra-supercritical boiler passed 168 hours trial operation,the problem of low reheat steam temperature occurred during low load operation.It has a great impact on the economical operation of the boiler.This article mainly analyzes the reason for the low raheat steam temperature of the boiler at low load operation.At the same time,the plan for adjusting and reconstructing of the reheater is given.