检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张妮萍 曹雪玲 张玲 Zhang Ni-ping;Cao Xue-ling;Zhang Ling(Center for Disease Control and Prevention of China Railway Shanghai Group Co.,Ltd.,Shanghai 200071,China)
机构地区:[1]中国铁路上海局集团有限公司上海铁路疾病预防控制所,上海200071
出 处:《福建分析测试》2024年第5期29-32,共4页Fujian Analysis & Testing
摘 要:目的:ICP-OES同时测定电焊烟尘中6种金属及其化合物的检测新方法。方法:采用微孔滤膜采样,微波消解仪消化样品,ICP-OES同时测定6种金属的含量。并对实验条件进行优化,考察了方法的线性参数、精密度、准确度等指标。结果:6种金属在测定范围内呈线性关系,相关系数均达到0.9999,方法检出限0.04~0.64μg/m^(3),加标回收率范围为95.2%~107.2%,相对标准偏差(RSD)均小于5%。结论:该方法简单、高效、准确,可用于测定电焊烟尘中的锰、镍、铬、铜、钼、钒6种金属及其化合物。Objective:A new method for the simultaneous determination of six metals and their compounds in welding fume by microwave digestion combined with ICP-OES was established.Methods:Samples were collected using microporous fil⁃ter membranes,digested with a microwave digestion instrument,and the content of six metals was determined simultaneous⁃ly by ICP.The experimental conditions were optimized,and the linear parameters,precision,accuracy and other indicators of the method were examined.Results:The six metals showed a linear relationship within the measurement range,with cor⁃relation coefficients reaching 0.9999.The determination limits of the method were in the range of 0.04-0.64μg/m^(3).The av⁃erage recovery rate was 95.2%-107.2%,and the relative standard deviation was less than 5%.Conclusion:The method is simple,efficient and accurate,and can be used for the determination of manganese,nickel,chromium,copper,molybde⁃num,vanadium and their compounds in welding dust.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.158