流量测量罐设计与数据修正研究  

Research on the Design and Data Correction of Flow Measurement Tanks

在线阅读下载全文

作  者:邓荣华 杨晓红 DENG Ronghua;YANG Xiaohong

机构地区:[1]德阳东汽电站机械制造有限公司,四川德阳618000 [2]四川顺安电子工程有限公司,四川德阳618000

出  处:《电力系统装备》2024年第8期117-119,共3页Electric Power System Equipment

摘  要:当前对电力系统相关设备的出厂要求越来越高,同时电厂对设备安装周期的要求也越来越短。为了提高出厂设备的可靠性,在设备出厂时进行性能试验,以此来验证出厂设备是否满足设计要求。文章结合生产实践,针对工厂自制罐式流量计测量原理及测量数据修正过程进行分析及阐述,以此验证设备流量参数准确性及可靠性。The requirements for factory equipment are becoming increasingly high,and the installation cycle of equipment is also becoming shorter.In order to improve the reliability of the factory equipment,performance tests are conducted at the time of equipment delivery to verify whether the factory equipment meets the design requirements.The article combines production practice to analyze and elaborate on the measurement principle and data correction process of self-made tank flow meters in factories,in order to verify the accuracy and reliability of equipment flow parameters.

关 键 词:罐式流量计 电力系统 流量测量原理 测量数据修正 

分 类 号:TM623[电气工程—电力系统及自动化]

 