检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵媛媛 雷建锋 ZHAO Yuanyuan;LEI Jianfeng(Core Facilities,Capital Medical University,Beijing 100069,China)
出 处:《实验技术与管理》2024年第9期35-40,共6页Experimental Technology and Management
摘 要:在过去几十年中,Micro CT已成为评估小动物骨骼微结构的金标准。然而Micro CT得到的定量指标会受到很多因素影响,如成像参数、重建像素大小和图像分割阈值等。为了提高相关实验准确性和可重复性,以及在各个研究间进行更可靠的比较,结合小鼠离体股骨的Micro CT实验,设计不同通量的标本及组合方案来验证骨微结构测量结果是否受其影响。结果表明,标本通量及组合方式的不同对骨微结构指标测量没有产生显著性影响,但高通量扫描会降低输出图像的质量,可能会减弱组间差异的检测能力,仍需注意其产生的影响。因此在确定实验方案前需探讨标本通量对实验结果是否产生影响,或者在整个研究中保持标本通量和标本摆放方式的一致性。[Objective]As a nondestructive three-dimensional imaging technique,micro-computed tomography(micro-CT)is the gold standard for evaluating the microstructure of the bone cortex and trabeculae.Many factors,such as scanning,processing,and evaluation of micro-CT,may affect the measurement results of the bone cortex and trabecular microstructure.However,it is not entirely clear how these factors affect the results.Scientific research often requires a large number of specimens.Micro-CT scanning is usually time-consuming,and it is common to increase the scanning flux by simultaneously scanning multiple bone specimens(such as mouse femurs).This study investigated the effects of different scanning sample fluxes on bone morphology and trabecular microstructure parameters.In addition,the study also investigated the effects of different placement methods of specimens with the same flux on cortical and trabecular microstructure parameters and the impact on the qualities of the image.[Methods]Right leg femurs were obtained from thirty 2-month-old male CD-1(IGS)mice.One,three,and five specimen fluxes combined with parallel and circular placement methods were used to perform micro-CT scans and reconstructions under the same settings.The obtained bone trabecular parameters were bone volume fraction,bone trabecular thickness,bone trabecular number,and bone trabecular gap.The cortical bone parameters obtained were cortical bone area,cortical bone thickness,and cortical bone volume fraction.The signal-to-noise ratio of the image was calculated by comparing the signal intensities of the bone cortex and background.To analyze the impact of sample flux and sample placement on the data and the degree of impact,other data were compared with the data obtained from single scanning as the control group.[Results]The experimental results showed the following:1)Different sample fluxes affected the measurement values of the microstructure parameters in the bone cortex and trabeculae.As the sample flux increased,the volume fraction of trabeculae
关 键 词:微型CT 骨皮质 骨小梁 微结构指标 扫描通量 标本摆放方法
分 类 号:R318.4[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.62