某大底盘多塔超高层部分框支剪力墙结构设计  

Design of Super High-rise Partial Frame-supported Shear Wall Structure with Large Chassis and Multi-tower

在线阅读下载全文

作  者:张鑫 刘云浪 吴欣玲 陈健 陈奇纳 史晓婷 ZHANG Xin;LIU Yunang;WU Xining;CHEN Jian;CHEN Qina;SHI Xiaoting(CCDI GROUP Shenzhen 518048,China)

机构地区:[1]悉地国际设计顾问(深圳)有限公司,深圳518048

出  处:《广东土木与建筑》2024年第9期53-56,共4页Guangdong Architecture Civil Engineering

摘  要:某大底盘多塔超高层部分框架剪力墙结构高152 m,位于7度区Ⅱ类场地,为超B级高层建筑,存在扭转不规则、尺寸突变、构件间断、抗扭刚度弱等四项不规则项。通过性能化分析,结构抗震性能可达到C级目标。转换层通过由整体指标到局部有限元的分析论证,提高了转换层关键构件的性能目标要求;多塔对裙房关联区域的影响由上往下逐层递减,采取增加附加钢筋、增加楼板厚度等措施,保证了结构的安全可靠。As a 152 m super high-rise building,which was located in intensity-category 7 and gradeⅡsite,the partial frame-supported shear wall structure system with large chassis and multi-tower was adopted.The tower was an exceeding B-level building with four irregular items,including torsional irregularity,size mutation,component discontinuity and weak torsional stiffness.According to the performance-based analysis,the seismic performance of the structure could reach the C-level target.The performance target of the transition key compo‐nents had improved through the analysis from overall index to local finite elements.The influence of the multi-tower decreased layer by lay‐er from top to bottom.Strengthen measures such as adding additional rebars and increasing the thickness of the slab were taken to ensure the safety and reliability of the overall structure.

关 键 词:超高层 大底盘多塔 部分框支剪力墙 高位转换 性能化设计 

分 类 号:TU973[建筑科学—结构工程]

 