作 者:Saroj Lamichhane Roseline Mostafa Bhaskaran Gopalakrishnan Dayakar G.Devaru
机构地区:[1]Regional Mechanical Field,AmazonWeb Services,Herndon,VA 20170,USA [2]Industrial and Management Systems Engineering,West Virginia University,Morgantown,WV 26505,USA [3]Industrial and Production Engineering,JSS Science&Technology University,Mysuru,570006,India
出 处:《Energy Engineering》2024年第10期2743-2767,共25页能源工程(英文)
基 金:funded in part by the Industrial Assessment Center Project;supported by grants fromthe US Department of Energy and by the West Virginia Development Office.
摘 要:Building energy performance is a function of numerous building parameters.In this study,sensitivity analysis on twenty parameters is performed to determine the top three parameters that have the most significant impact on the energy performance of buildings.Actual data from two fully operational commercial buildings were collected and used to develop a building energy model in the Quick Energy Simulation Tool(eQUEST).The model is calibrated using the Normalized Mean Bias Error(NMBE)and Coefficient of Variation of Root Mean Square Error(CV(RMSE))method.The model satisfies the NMBE and CV(RMSE)criteria set by the American Society of Heating,Refrigeration,and Air-Conditioning(ASHRAE)Guideline 14,Federal Energy Management Program(FEMP),and International Performance Measurement and Verification Protocol(IPMVP)for building energy model calibration.The values of the parameters are varied in two levels,and then the percentage change in output is calculated.Fractional factorial analysis on eight parameters with the highest percentage change in energy performance is performed at two levels in a statistical software JMP.For building A,the top 3 parameters from the percentage change method are:Heating setpoint,cooling setpoint and server room.From fractional factorial design,the top 3 parameters are:heating setpoint(p-value=0.00129),cooling setpoint(p-value=0.00133),and setback control(p-value=0.00317).For building B,the top 3 parameters from both methods are:Server room(pvalue=0.0000),heating setpoint(p-value=0.00014),and cooling setpoint(p-value=0.00035).If the best values for all top three parameters are taken simultaneously,energy efficiency improves by 29%for building A and 35%for building B.
关 键 词:Energy efficiency EQUEST energy consumption building energy modeling