检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:秦伟[1] 邹庆江 曹忠友 冷江潼 王建伟 焦健 黄勇鹏 李彦辉 王亮亮 包民业 代寿森 Qin Wei;Zou Qingjiang;Cao Zhongyou;Leng Jiangtong;Wang Jianwei;Jiao Jian;Huang Yongpeng;Li Yanhui;Wang Liangliang;Bao Minye;Dai Shousen(Shandong Electric Power Engineering Consulting Institute Co.,Ltd.,Jinan;Inner Mongolia Mengdong Energy Co.,Ltd.,Ewenke Power Plant,Hulun Buir;Shandong Antai Intelligent Engineering Co.,Ltd.,Jinan;Sichuan Hongyuan Construction Engineering Co.,Ltd.,Chengdu)
机构地区:[1]山东电力工程咨询院有限公司,济南 [2]内蒙古蒙东能源有限公司鄂温克电厂,呼伦贝尔 [3]山东安泰智能工程有限公司,济南 [4]四川宏远建筑工程有限公司,成都
出 处:《暖通空调》2024年第10期137-142,共6页Heating Ventilating & Air Conditioning
摘 要:严寒地区电厂锅炉房是具有内热源的超高大空间建筑,冬季底层负压大,供暖效果难以保障。本文提出了从锅炉房上部送入室外空气的解决方案。采用该方案可以使室内压力增大,底层负压和冷风渗透量减小,还能使热量向下传递。由于锅炉房设备散热量远大于供暖热负荷,在送风量合适的情况下,可关停供暖系统而不影响底层的供暖效果,既保证了底层设备不被冻坏,又节省了供暖热能,还改善了锅炉房上部的工作环境。The boiler house of power plants in severe cold zone is a super tall space building with internal heat sources,and the negative pressure on the ground floor is high in winter,making it difficult to ensure the heating effect.In this paper,the solution to supply outside air from the upper part of the boiler house is proposed.This scheme can increase the indoor pressure,reduce the negative pressure and cold air penetration on the ground floor,and transfer heat downward.Because the heat dissipation of the boiler house equipment is much greater than the heating load,in the case of suitable air supply,the heating system can be shut down without affecting the heating effect of the ground floor,which not only ensures that the equipment on the ground floor is not frozen,but also saves the heating energy,and also improves the working environment of the upper part of the boiler house.
关 键 词:严寒地区 锅炉房 供暖 超高大空间建筑 底层 负压控制 余热利用 节能
分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.119.0.207