分光光度法测定水泥中水溶性二价镉的含量测量不确定度分析研究  

Analysis Study on the Measurement Uncertainty in Determining the Content of Water-soluble Divalent Cadmium in Cement by Spectrophotometry

在线阅读下载全文

作  者:张烁 邹旭明 ZHANG Shuo;ZHOU Xuming(Guangdong Meizhou Quality&Metrology Supervision and Testing Instition;National Cement&Products Quality Inspection and Testing Center(GuangDong))

机构地区:[1]广东省梅州市质量计量监督检测所 [2]国家水泥及制品质量检验检测中心(广东)

出  处:《广东建材》2024年第10期51-54,共4页Guangdong Building Materials

摘  要:水泥中水溶性重金属离子的检测中,二价镉作为有毒的重金属元素是较为重要的重金属离子之一。在使用分光光度法来测定水泥中水溶性二价镉含量中,为提高检测的准确性,对检测仪器、称量设备等引入的不确定度因素进行研究,得出二价镉含量的测量不确定度(扩展因子K=2)为3.74%,满足实际需求。In the detection of water-soluble heavy metal ions in cement,divalent cadmium,as a toxic element of heavy metal,is one of the most important heavy metal ions.In the use of spectrophotometry to determine the water-soluble divalent cadmium content in cement,in order to improve the accuracy of the test,the uncertainty factors introduced by the testing instrument,weighing equipment,etc.were studied.At the end,the measurement uncertainty of water-soluble divalent cadmium in cement is obtained to be 3.74%(the expansion factor K=2),which meets the practical requirements.

关 键 词:水泥 二价镉 紫外可见分光光度计 不确定度 

分 类 号:TQ172.1[化学工程—水泥工业] O657.3[化学工程—硅酸盐工业]

 