检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:惠海军 HUI Haijun(Hunan Company of PipeChina,Changsha 410022,China)
机构地区:[1]国家石油天然气管网集团有限公司湖南分公司,湖南长沙410022
出 处:《化工管理》2024年第27期134-137,共4页Chemical Management
摘 要:针对某长输埋地输气管道,其阴极保护系统辅助阳极地床接地电阻偏高,给系统运行带来不利影响。因此,文章从地质条件、阳极床材料、间距、尺寸、材料类型方面对该问题进行分析并提出有效解决方案,并对其效果进行了评价。结果表明,该优化措施有效降低了辅助阳极地床接地电阻,增大了阴保电流输出,使断电电位控制在规范允许的范围之内,缓减了管道腐蚀。For a Long distance buried gas pipeline,the auxiliary anode bed grounding resistance of the cathodic protection system is on the high side,which brings adverse influence to the system operation.In this paper,the geological conditions,anode bed materials,spacing,size and material types are analyzed and effective solutions are put forward,and their effects are evaluated.The results show that the optimized method can effectively reduce the grounding resistance of the auxiliary anode bed,increase the output of the cathodic protection current,control the switch-off potential within the allowable range of the specification,and slow down the pipeline corrosion.
分 类 号:TE973[石油与天然气工程—石油机械设备]