摘 要:对于电流互感器,投运前必须进行交接性试验,以保证电流互感器满足工作标准要求。为此,应按照国家标准对校内一台油浸式电流互感器开展交接性试验,分析各种试验方法和特点,验证电流互感器交接性试验各项目试验方法和原理,全面了解设备投运的准入条件,以保证电力设备安全稳定投入使用。For current transformers,a handover test must be conducted before operation to ensure that the current transformers meet the working standard requirements.To this end,a handover test should be conducted on an oil immersed current transformer on campus in accordance with national standards,analyzing various test methods and characteristics,verifying the test methods and principles of each item in handover test of the current transformer,comprehensively understanding the admission conditions for equipment operation,and ensuring the safe and stable use of power equipment.