负温下风电混塔拼接胶的抗流挂性能和可工作时间研究  

Study on anti-sagging performance and working time of wind power hybrid tower splicing adhesive under negative temperature

在线阅读下载全文

作  者:李博洋 吴香国[1,2,3] 张明熠 周瑞权 刘忠岩 王学振 王建福 罗仕刚 单韧 LI Boyang;WU Xiangguo;ZHANG Mingyi;ZHOU Ruiquan;LIU Zhongyan;WANG Xuezhen;WANG Jianfu;LUO Shigang;SHAN Ren(Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education,Harbin Institute of Technology,Harbin 150090,China;Key Lab of Smart Prevention and Mitigation of Civil Engineering Disasters of the Ministry of the Industry and Information Technology,Harbin Institute of Technology,Harbin 150090,China;College of Civil Engineering,Fuzhou University,Fuzhou 350108,China;CFHI(HEILONGJIANG)Wind Power Hybrid Tower Co.,Ltd.,Qiqihar 161042,China;Shanghai Electric Wind Power Group Co.,Ltd.,Shanghai 200233,China;SINO-SINA Building Materials Co.,Ltd.,Zhengzhou 452300,China;Sika(China)Co.,Ltd.,Suzhou 215121,China;Carbon Technology Group Co.,Ltd.,Tianjin 300385,China;Hunan Goodbond Civil Engineering Technology Development Co.,Ltd.,Changsha 410221,China)

机构地区:[1]哈尔滨工业大学结构工程灾变与控制教育部重点实验室,黑龙江哈尔滨150090 [2]哈尔滨工业大学土木工程智能防灾减灾工业和信息化部重点实验室,黑龙江哈尔滨150090 [3]福州大学土木工程学院,福建福州350108 [4]一重(黑龙江)风电混塔有限公司,黑龙江齐齐哈尔161042 [5]海电气风电集团股份有限公司,上海200233 [6]中德新亚建筑材料有限公司,河南郑州452300 [7]西卡(中国)有限公司,江苏苏州215121 [8]卡本科技集团股份有限公司,天津300385 [9]湖南固特邦土木科技发展有限公司,湖南长沙410221

出  处:《混凝土与水泥制品》2024年第10期23-26,33,共5页China Concrete and Cement Products

基  金:国家自然科学基金项目(51811540401、52178195)。

摘  要:总结了结构拼接胶的研究现状,对比了现有相关标准对结构拼接胶的技术要求差异,研究了负温(-5℃)环境下4种风电混塔结构用拼接胶的抗流挂性能和可工作时间。结果表明:4种结构拼接胶在负温环境下的抗流挂性能均较好,可工作时间与流挂长度成正比关系;当环境温度高于结构拼接胶的适用温度时,会加快固化速率,缩短可工作时间,容易导致节段拼接性能有所损失甚至失效;当环境温度低于结构拼接胶的适用温度时,会减缓固化速率甚至不固化,影响施工进程,也易使节段发生硬接触而破坏;应结合风电混塔的实际施工环境条件选用合适的结构拼接胶。The research status of structural splicing adhesives was summarized,and the differences in technical requirements for structural splicing adhesives in existing relevant standards were compared.The anti-sagging performance and working time of four types of splicing adhesives used in wind power hybrid tower structures under negative temperature(-5℃)environment were studied.The results show that the anti-sagging performance of the four types of structural splicing adhesives is good in negative temperature environments,and the working time is proportional to the sagging length.When the ambient temperature is higher than the applicable temperature of structural splicing adhesive,it will accelerate the curing rate,shorten the working time,and easily lead to loss or even failure of segment splicing performance.When the ambient temperature is lower than the applicable temperature of structural splicing adhesive,it will slow down the curing rate or even not cure,affect the construction process,and easily cause hard contact and damage to the section.Suitable structural splicing adhesive should be selected based on the actual construction environment conditions of wind power hybrid towers.

关 键 词:风电混塔 结构拼接胶 负温 施工性能 