机构地区:[1]福建省计量科学研究院
出 处:《计量与测试技术》2024年第9期80-82,85,共4页Metrology & Measurement Technique
摘 要:基于标准电阻法,对3种不同型号的精密铂电阻测温仪进行示值误差、示值波动性及短期漂移性能对比试验。同时,针对不同的工作环境温度及标准铂电阻温度计ITS-90参数对测量结果的影响进行测试。结果表明:该测温仪准确度高、波动性小,且个别样品短期漂移可达0.01℃;工作环境温度对其不同型号的影响量不同,且温度计的参数对测量结果影响较小。Based on the standard resistance method,a comparison test on the performance of indication error,indi-cation fluctuation and short-term drift of three kinds of precision platinum resistance thermometers was carried out.At the same time,the influence of different working environment temperature and standard platinum resistance thermometer ITS-90 parameters on the measurement results is tested.The results show that the thermometer has high accuracy and low fluctuation,and the short-term drift of individual samples can reach 0.01℃.The influence of working environment temperature on different models is different,and the parameter of the thermometer has little influence on the measurement result.
关 键 词:精密铂电阻测温仪 标准电阻法 标准铂电阻温度计 影响因素
分 类 号:TH811[机械工程—仪器科学与技术]