作 者:李天麟 郭祺[1] 王鑫[1] 冀浩然 涂春鸣[1] 侯玉超 李俊豪 LI Tianlin;GUO Qi;WANG Xin;JI Haoran;TU Chunming;HOU Yuchao;LI Junhao(National Electric Energy Conversion and Control Engineering Technology Research Center(Hunan University),Changsha 410082,Hunan Province,China;Key Laboratory of Smart Grid(Tianjin University),Ministry of Education,Nankai District,Tianjin 300072,China)
机构地区:[1]国家电能变换与控制工程技术研究中心(湖南大学),湖南省长沙市410082 [2]智能电网教育部重点实验室(天津大学),天津市南开区300072
出 处:《电网技术》2024年第10期4358-4366,I0125,共10页Power System Technology
基 金:中国博士后基金第16批特别基金(站中)(2023T160207)。
摘 要:随着分布式能源与随机负荷的大量接入,配电台区三相负荷不平衡与变压器轻重载运行问题日益突出,这将威胁台区安全可靠运行。然而,既有关于互联台区的研究鲜有兼顾三相不平衡与轻重载运行问题的综合治理。对此,该文提出一种基于四桥臂智能软开关(four-leg soft open point,F-SOP)的柔性互联配电台区三相不平衡与轻重载综合调控策略。首先,分析了F-SOP和变压器的综合损耗特性,结果表明不平衡度和负载率均会影响设备运行效率;其次,建立三相不平衡与轻重载综合调控策略模型,设立变压器输出功率不平衡度与负载率的指标约束,以系统综合损耗最小为优化目标求解F-SOP最优调控指令。接着,针对F-SOP拓扑架构及其功率调控的需求,提出一种改进对等控制方法,进一步提高F-SOP稳定性能与动态性能,确保综合调控策略的实现。最后,通过算例分析与仿真实验验证了所提综合调控策略的有效性和可行性。With the extensive integration of distributed energy and random loads,the problem of three-phase load imbalance and transformer light and heavy load operation in the distribution station area is becoming increasingly prominent,which will threaten the safe and reliable operation of the station area.However,existing research on interconnected substations only focuses on a single regulatory objective,and few comprehensive governance issues balance three-phase imbalance and light and heavy load operation.The article proposes a comprehensive control strategy for three-phase imbalance and light and heavy loads in the flexible interconnected distribution station area based on a four-leg soft open point(F-SOP).Firstly,the comprehensive loss characteristics of F-SOP and transformers were analyzed,and the results showed that both imbalance and load rate would affect the operational efficiency of the equipment.Secondly,a comprehensive control strategy model for three-phase imbalance and light and heavy loads must be established,indicator constraints for transformer output power imbalance and load rate established,and the F-SOP optimal control command must be solved with the optimization goal of minimizing system comprehensive loss.Next,an improved peer-to-peer control method is proposed to improve the stability and dynamic performance of F-SOP,ensuring the implementation of comprehensive control strategies,in response to F-SOP topology architecture and power regulation requirements.Finally,the effectiveness and feasibility of the proposed comprehensive control strategy were verified through numerical analysis and simulation experiments.
关 键 词:柔性互联配电台区 智能软开关 三相不平衡 轻重载 综合调控
分 类 号:TM721[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.12.149.233