检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:罗沁 王嘉梅[1,2] 黄璇 李华鑫 盛祥瑞 Luo Qin;Wang Jiamei;Huang Xuan;Li Huaxin;Sheng Xiangrui(School of Electrical and Information Engineering,Yunnan Minzu University,Kunming 650504,China;Yunnan Key Laboratory of Unmanned Autonomous System,Kunming 650504,China;State Grid Chongqing Power Company,Kai County Power Supply Branch,Chongqing 405400,China)
机构地区:[1]云南民族大学电气信息工程学院,昆明650504 [2]云南省无人自主系统重点实验室,昆明650504 [3]国网重庆市电力公司开州供电分公司,重庆405400
出 处:《电子测量技术》2024年第12期18-27,共10页Electronic Measurement Technology
基 金:国家自然科学基金(61963038);云南省教育厅科研基金重大专项(ZD2013013)资助。
摘 要:孤岛式直流微电网系统需要配置多组DESUs,以应对不同的负荷需求和能源波动。考虑DESUs具有不同容量时,由于线路中阻抗不匹配,SOC均衡效果受到严重影响,为此,提出一种考虑不同容量的多储能SOC均衡控制策略。首先,通过含加速因子的指数函数建立SOC与下垂系数之间的关系,提升下垂系数对SOC均衡后期变化的灵敏性,实现下垂系数的自适应调节。各DESU仅通过稀疏通信网络与邻居节点交换状态信息,并采用动态一致性算法获取全局平均状态信息。设计一种多目标控制器,其能够在补偿母线电压跌落的同时实现负荷功率的准确分配,消除不匹配线阻的影响,减少控制流程,减轻系统通信负担。最后,基于MATLAB/Simulink软件搭建了仿真模型,并在各种复杂工况下证实了所提控制策略的有效性。Islanded DC microgrid systems need to be configured with multiple DESUs to cope with different load demands and energy fluctuations.Considering DESUs with different capacities,the SOC balancing effect is seriously affected due to the impedance mismatch in the line;for this reason,a multi-storage SOC balancing control strategy considering different capacities is proposed.Firstly,the relationship between SOC and the droop coefficient is established by an exponential function containing an acceleration factor,which improves the sensitivity of the droop coefficient to the late change of SOC balancing and realizes the adaptive adjustment of the droop coefficient.Each DESU only exchanges state information with neighboring nodes through a sparse communication network and adopts a dynamic consistency algorithm to obtain the global average state information.A multi-objective controller is designed,capable of compensating bus voltage dips while achieving accurate distribution of load power,eliminating the effect of mismatched line resistance,reducing the control process,and alleviating the system communication burden.Finally,a simulation model is built based on MATLAB/Simulink software,and the effectiveness of the proposed control strategy is confirmed under various complex operating conditions.
关 键 词:直流微电网 储能单元 荷电状态 多目标控制器 电压恢复 功率分配
分 类 号:TM721.1[电气工程—电力系统及自动化] TN915[电子电信—通信与信息系统]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.211