Detector performance of the Gamma-ray Transient Monitor onboard DRO-A satellite  被引量:1

在线阅读下载全文

作  者:Pei-Yi Feng Zheng-Hua An Da-Li Zhang Chen-Wei Wang Chao Zheng Sheng Yang Shao-Lin Xiong Jia-Cong Liu Xin-Qiao Li Ke Gong Xiao-Jing Liu Min Gao Xiang-Yang Wen Ya-Qing Liu Xiao-Yun Zhao Fan Zhang Xi-Lei Sun Hong Lu 

机构地区:[1]Key Laboratory of Particle Astrophysics,Institute of High Energy Physics,Chinese Academy of Sciences,Beijing 100049,China [2]University of Chinese Academy of Sciences,Beijing 100049,China [3]State Key Laboratory of Particle Detection and Electronics,Institute of High Energy Physics,Chinese Academy of Sciences,Beijing 100049,China

出  处:《Science China(Physics,Mechanics & Astronomy)》2024年第11期75-90,共16页中国科学:物理学、力学、天文学(英文版)

基  金:supported by the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant Nos.XDA30050100 and XDA30030000);the National Natural Science Foundation of China (Grant Nos.12173038,11775251,12273042,and 12075258);funded by the Strategic Priority Research Program on Space Science (Grant No.XDA15360000) of the Chinese Academy of Sciences (CAS)。

摘  要:The Gamma-ray Transient Monitor(GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A(DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 ke V to 1 MeV. The GTM was equipped with five Gamma-ray Transient Probe(GTP) detector modules utilizing a NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP uses a dedicated dual-channel coincident readout design. In this work, we first studied the impact of different coincidence times on the detection efficiency and ultimately selected a 0.5 μs time coincidence window for offline data processing. To test the performance of the GTPs and validate the Monte-Carlo-simulated energy response, we conducted comprehensive ground calibration tests using the Hard X-ray Calibration Facility(HXCF) and radioactive sources, including the energy response, detection efficiency, spatial response, bias-voltage response, and temperature dependence. We extensively present the ground calibration results and validate the design and mass model of the GTP detector, thus providing the foundation for in-flight observations and scientific data analysis.

关 键 词:NaI(Tl)detector energy response ground calibration gamma-ray detector DRO-A satellite 

分 类 号:V447.1[航空宇航科学与技术—飞行器设计] P172.3[天文地球—天文学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象