Design,characterisation,and clinical evaluation of a novel porous Ti-6Al-4V hemipelvic prosthesis based on Voronoi diagram  

在线阅读下载全文

作  者:Zhuangzhuang Li Yi Luo Minxun Lu Yitian Wang Linsen Zhong Yong Zhou Zhenfeng Duan Li Min Chongqi Tu 

机构地区:[1]Orthopaedic Research Institute and Department of Orthopaedics,West China Hospital,Sichuan University,Chengdu,Sichuan Province,China [2]Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province,Chengdu,Sichuan Province,China [3]Tianqi Additive Manufacturing Co.,Ltd,Chengdu,Sichuan Province,China [4]Department of Orthopaedic Surgery,Sarcoma Biology Laboratory,Sylvester Comprehensive Cancer Centre,and The University of Miami Miller School of Medicine,Miami,FL,USA

出  处:《Biomaterials Translational》2024年第3期314-324,共11页生物材料转化电子杂志(英文)

基  金:supported by Qingdao Research Institutes of Sichuan University,Research of Biomedical Materials and 3D Printing Related Products(No.20GZ30301).

摘  要:Three-dimensional printed Ti-6Al-4V hemipelvic prosthesis has become a current popular method for pelvic defect reconstruction.This paper presents a novel biomimetic hemipelvic prosthesis design that utilises patient-specific anatomical data in conjunction with the Voronoi diagram algorithm.Unlike traditional design methods that rely on fixed,homogeneous unit cell,the Voronoi diagram enables to create imitation of trabecular structure(ITS).The proposed approach was conducted for six patients.The entire contour of the customised prosthesis matched well with the residual bone.The porosity and pore size of the ITS were evaluated.The distribution of the pore size ranged from 500 to 1400μm.Porosity calculations indicated the average porosity was 63.13±0.30%.Cubic ITS samples were fabricated for micrograph and mechanical analysis.Scanning electron microscopy images of the ITS samples exhibited rough surface morphology without obvious defects.The Young’s modulus and compressive strength were 1.68±0.05 GPa and 174±8 MPa,respectively.Post-operative X-rays confirmed proper matching of the customised prostheses with the bone defect.Tomosynthesis-Shimadzu metal artifact reduction technology images indicated close contact between the implant and host bone,alongside favourable bone density and absence of resorption or osteolysis around the implant.At the last follow-up,the average Musculoskeletal Tumour Society score was 23.2(range,21-26).By leveraging additive manufacturing and Voronoi diagram algorithm,customised implants tailored to individual patient anatomy can be fabricated,offering wide distribution of the pore size,reasonable mechanical properties,favourable osseointegration,and satisfactory function.

关 键 词:3D printing biomimetic prosthesis bone tumour pelvic defect reconstruction porous structure 

分 类 号:R318[医药卫生—生物医学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象