基于台区剩余电流关联性分析的接线错误漏电用户识别方法  被引量:1

Identification Method for Users with Wiring Errors and Leakage Current Based on Correlation Analysis of Residual Current in Distribution Station Area

在线阅读下载全文

作  者:向骊羽 周义博 苏盛[1] 赖志强 冯萧飞 李彬[1] XIANG Liyu;ZHOU Yibo;SU Sheng;LAI Zhiqiang;FENG Xiaofei;LI Bin(School of Electrical and Information Engineering,Changsha University of Science and Technology,Changsha 410114,China;Dongguan Power Supply Bureau of Guangdong Power Grid Corporation,Dongguan 523009,China)

机构地区:[1]长沙理工大学电气与信息工程学院,湖南省长沙市410014 [2]广东电网有限责任公司东莞供电局,广东省东莞市523009

出  处:《电力系统自动化》2024年第20期191-199,共9页Automation of Electric Power Systems

基  金:国家自然科学基金资助项目(51777015);中国南方电网有限责任公司科技项目(GDKIXM20230433(03190KC2304019))。

摘  要:低压配电网中,台区剩余电流与零线、地线接线错误用户的用电行为具有密切关联性,而正常用户对台区剩余电流的影响较小。文中提出一种基于台区剩余电流关联性分析的接线错误漏电用户识别方法,根据接线错误用户的负荷电流与台区总剩余电流之间的内在关系来识别接线错误的漏电用户。首先,指出了基于电流幅值回归分析识别异常用户的理论缺陷;然后,结合台区剩余电流实部时序数据和台区用户负荷电流实部时序数据构建状态方程和测量方程,采用卡尔曼滤波进行状态估计,通过计算各用户负荷电流与台区剩余电流的相关系数,达到识别接线错误的漏电用户的目的;最后,基于已查证的含接线错误的漏电台区的实际数据,验证了所提方法的有效性。In the low-voltage distribution network,the residual current in the distribution station area is closely related to the consumption behavior of users with wiring errors of neutral lines and grounding lines,while the normal users have little influence on the residual current in the distribution station area.In this paper,an identification method for users with wiring errors and leakage current based on correlation analysis of residual current in distribution station area is proposed,which identifies the users with wiring errors according to the internal relationship between the load current of the users with wiring errors and the total residual current in the distribution station area.First,the theoretical defects of abnormal user identification based on current amplitude regression analysis is pointed out.Then,the state equation and measurement equation are constructed by combining the real part time series data of the residual current and the user load current in the distribution station area.Kalman filter is used to estimate the state,and the correlation coefficient between the load current of each user and the residual current in the distribution station area is calculated to identify the users with wiring errors and leakage current.Finally,the validity of the proposed method is verified based on the verified actual data of the distribution station area with wiring errors and leakage current.

关 键 词:配电台区 漏电 用户 接线错误 剩余电流 状态空间模型 卡尔曼滤波 

分 类 号:TM73[电气工程—电力系统及自动化]

 