作 者:李袁昊 常刘勇 李光泽 周泉 陈龙飞[4] LI Yuanhao;CHANG Liuyong;LI Guangze;ZHOU Quan;CHEN Longfei(College of Mechanical and Electrical Engineering,China Jiliang University,Hangzhou 310018,China;Zhongfa Aviation Institute of Beihang University,Hangzhou 310005,China;College of Optical and Electronic Technology,China Jiliang University,Hangzhou 310018,China;School of Energy and Power Engineering,Beihang University,Beijing 100191,China)
机构地区:[1]中国计量大学机电工程学院,浙江杭州310018 [2]杭州市北京航空航天大学中法航空研究院,浙江杭州310005 [3]中国计量大学光学与电子科技学院,浙江杭州310018 [4]北京航空航天大学能源与动力工程学院,北京100191
出 处:《中国计量大学学报》2024年第3期390-398,共9页Journal of China University of Metrology
基 金:国家自然科学基金项目(No.52306181,52306184)。
摘 要:目的:在用车尾气排放颗粒物数目含量检测技术和设备国产化。方法:基于凝结核增长计数原理,采用自稀释结构,并调整温度设置,研发了纳米级细颗粒物计数仪器,并在洁净间进行了标定实验,同时,基于标定完成的自研CPC仪器对在用车排放尾气颗粒物数目含量进行了实地测量。结果:在使用自稀释结构,采样温度为6~50℃下,自研仪器的D50达到了9.2 nm,满足机动车D50为23±1 nm的检测要求,仪器瞬态响应误差为9.53%,检测范围在0~5×10^(4)个/mL,满足仪器误差指标。此外,针对在用车排放尾气的实地测量结果表明,自研CPC具有较好的辨识能力,可以准确地捕捉到不同量级的颗粒物数目含量变化趋势,且自研CPC与TSI CPC的峰值相对误差变化均低于10%。结论:研制的仪器达到机动车尾气检测标准,且仪器检测范围内一致性较高。Aims:This paper aims to achieve the local technology and equipment for detecting the concentrations and particles in vehicle exhaust emissions.Methods:This study developed a nanoscale fine particle counting instrument based on the principle of nucleation growth counting.Adopting a self dilution structure and adjusting the temperature setting,calibration experiments were conducted in a controlled clean room environment.Results:With the use of a self-dilution structure and sampling temperature of 6~50℃,the D 50 of the instrument reached 9.2 nm,meeting the detection requirements of 23±1 nm for motor vehicles.The transient response error of the instrument was 9.53%,the detection range was from 0 to 5×10^(4) particles/mL,thus meeting the instrument error index.The on-site measurements of exhaust emissions from in-use vehicles showed that the developed condensation particle counter(CPC)accurately identified the changes in particle concentration across different magnitudes.Moreover,both the developed CPC and the TSI CPC exhibited peak relative error changes of less than 10%.Conclusions:The developed instrument meets the standard of motor vehicle exhaust testing with high consistency and detection ranges.
关 键 词:颗粒物数目含量 发动机排放 仪器标定 在用车检测 细颗粒物
分 类 号:TH715[机械工程—测试计量技术及仪器]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222