Model-based investigation on building thermal mass utilization and flexibility enhancement of air conditioning loads  

在线阅读下载全文

作  者:Yue Sun Tianyi Zhao Shan Lyu 

机构地区:[1]Institute of Building Energy,School of Infrastructure Engineering,Dalian University of Technology,Dalian,116024,China [2]School of Civil Engineering,Chongqing University,Chongqing 400045,China

出  处:《Building Simulation》2024年第8期1289-1308,共20页建筑模拟(英文)

基  金:supported by the National Natural Science Foundation of China(Grant No.52078096);the Natural Science Foundation Joint Fund of Liaoning Province(Grant No.2023-MSBA-023);2023 Dalian University of Technology-Cardiff University Cooperation and Exchange Foundation Project,2023 International Exchange Foundation Project of“Co-Creation of Excellence Program”from Dalian University of Technology(Grant No.DUTIO-ZG-202307);the Key Project of DUT for International Students Studying and Researching in China:Innovation and Practice of Talent Cultivation Model in the Field of Smart Buildings for the“Belt and Road"Initiative(Grant No.1103-82120001).

摘  要:Building air conditioning systems(ACs)can contribute to the stable operation of power grids by participating in peak load shaving programs,but the participants need a fast and accurate zone temperature prediction model,e.g.,the detailed room thermal-resistance(RC)model,to improve peak shaving effect and avoid obvious thermal discomfort.However,when applying the detailed room RC model to multi-zone buildings,conventional studies mostly consider the heat transfer among neighboring rooms,which contributes little to the prediction accuracy improvement,but leads to complicated model structure and heavy computation.Thus,a distributed RC model is developed for multi-zone buildings in this study.Compared to conventional models,the proposed model considers the total heat transfer between the building and the air,and ignores the heat transfer among indoor air in neighboring rooms through internal walls with heavy thermal mass,thereby having comparable temperature prediction accuracy,simpler structure,and stronger robustness.Based on the model,the effectiveness of passive pre-cooling strategies in reducing the air conditioning loads during peak periods is investigated.Results indicate that the thermal insulation performance of opaque building envelope is quite important to the flexibility enhancement of air conditioning loads.With an uninsulated building envelope,passive pre-cooling is useless for the peak load shaving.In comparison,well insulated opaque building envelope enables the building thermal mass to be utilized through passive pre-cooling,which leads to the air conditioning loads during peak periods being further reduced by about 12%.

关 键 词:RC model passive pre-cooling internal thermal mass building energy flexibility 

分 类 号:TU111.1[建筑科学—建筑理论]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象