Effects of increasing the degree of building height asymmetry on ventilation and pollutant dispersion within street canyons  

在线阅读下载全文

作  者:Kwang Song Jon Song Il Jong Sung Hyok Ri Ju Yon Ko Sung Gi Ko Hun Kim Tok Song Ryang Chung Hyok Sin 

机构地区:[1]School of Environment and Architecture,University of Shanghai for Science and Technology,Shanghai 200093,China [2]School of Metallic Engineering,Kim Chaek University of Technology,Central District,Pyongyang 900093,Democratic People’s Republic of Korea [3]Faculty of Physics,Kim Chaek University of Technology,Central District,Pyongyang 900093,Democratic People’s Republic of Korea [4]Natural Science Center,Kim Il Sung University,Taesong District,Pyongyang 900093,Democratic People’s Republic of Korea

出  处:《Energy and Built Environment》2024年第5期727-740,共14页能源与人工环境(英文)

摘  要:Rational urban design helps to build sustainable cities with high ventilation capacity and pollutant removal ca-pacity,but the effect of building height on ventilation and pollutant dispersion inside asymmetric canyons has not been fully studied.In this paper,we studied the effect of increasing the degree of building height asym-metry(DBHA)on canyon ventilation and pollutant diffusion in shallow and deep asymmetric street canyons by considering six different building height ratios(BHR=3/4,1/2,1/3,4/3,2/1 and 3/1).The results show that increasing the DBHA in asymmetric canyons can improve the ventilation and pollutant removal capacity.For step-up canyons,increasing the downwind building height is very useful to improve ventilation and pollutant re-moval.For shallow/deep step-up canyons with BHR=1/3,the air exchange rate(ACH)increased to 211.2%and 380.1%of the flat canyons,respectively.The spatially-average pollutant concentration in the pedestrian zones(leeward Kavg∗ang windward Kavg∗)decreases significantly with the increase of DBHA,especially for the deep step-up canyon with BHR=1/3,the leeward Kavg∗and windward Kavg∗decrease to 15.3%and 3%,respectively.Also,increasing the upwind building height can also improve the ventilation capacity in the step-down canyons.For the deep step-down canyon with BHR=3/1,the leeward Kavg∗and windward Kavg∗decreased to 40.6%and 24.1%of the deep flat canyon,respectively.Notably,the ventilation capacity is very low for step-down canyons with BHR=4/3,and for step-down canyons with BHR≥2/1,the ventilation capacity and pollutant removal capacity increase significantly with the increase of DBHA.Therefore,in urban planning,step-down canyons with BHR=4/3 should be avoided and designed to satisfy the condition of BHR≥2/1.These findings will be a valuable reference for urban designers to build sustainable cities with high ventilation capacity.

关 键 词:Building height Asymmetric street canyon Ventilation Traffic pollutant Sustainable city 

分 类 号:TU834[建筑科学—供热、供燃气、通风及空调工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象