作 者:熊晓泉 彭立沙 邱湘伟 XIONG Xiaoquan;PENG Lisha;QIU Xiangwei(Guangzhou Nanyang Cable Group Co.,Ltd.,Guangzhou 511356,China)
出 处:《电线电缆》2024年第5期27-30,35,共5页Wire & Cable
摘 要:随着电力系统的发展,行业对电缆耐火安全性能的要求不断提高。文中深入研究了柔性耐火电缆的耐火安全性能,并对主流耐火电缆的执行标准和耐火试验方法进行对比,为后续研究提供了理论基础。通过对比柔性耐火电缆耐火试验中缆芯内部温度、高温绝缘电阻、内部压力、耐火电缆载流量和电缆表面温度等的变化,综合各项研究成果,提出了针对性建议,以提升柔性耐火电缆的耐火安全性能,为电缆设计和选型提供参考。With the development of power system,the requirements for fire safety performance of cables are constantly increasing.Fire safety performance of flexible fire-resistant cables were developed,mainstream fireresistant cable implementation standards and fire-resistant test methods were compared,and providing a theoretical basis for subsequent research.Next,internal temperature,high-temperature insulation resistance,internal pressure,fire-resistant cable current carrying capacity,and cable surface temperature during the fire resistance test of flexible fire-resistant cables were studied and compared.Based on the comprehensive research results,targeted suggestions are proposed to improve the fire safety performance of flexible fire-resistant cables,providing reference for cable design and selection.
分 类 号:TM249.3[一般工业技术—材料科学与工程]