作 者:李燕[1] 宁攀良 姜岳明[2] Li Yan;Ning Panliang;Jiang Yueming(Chemical Poisoning and Heavy Metal Detection Center,Guangxi Zhuang Autonomous Region Institute for the Prevention and Treatment of Occupational Disease,Nanning 530021,China;School of Public Health,Guangxi Medical University,Nanning 530021,China)
机构地区:[1]广西壮族自治区职业病防治研究院化学中毒与重金属检测中心,南宁530021 [2]广西医科大学公共卫生学院,南宁530021
出 处:《中华劳动卫生职业病杂志》2024年第9期695-699,共5页Chinese Journal of Industrial Hygiene and Occupational Diseases
基 金:广西壮族自治区卫生健康委员会科技研究计划课题(Z-A20230411)。
摘 要:目的建立电感耦合等离子体质谱(ICP-MS)法同时测定全血中铍、钒、铬、锰、铁、钙、镁、钡、钴、镉、铜、锌、砷、硒、钛、锶、镍、钼、锡、锑、铊和铅22种元素含量的方法。方法于2023年9月,通过优化仪器检测模式、样品前处理方式以及稀释倍数等参数确定分析条件,全血样品用体积分数为0.1%硝酸和0.05%曲拉通X-100混合溶液稀释后,用高速离心机以2000 r/min离心2 min,取上清液进ICP-MS仪进行22种元素含量的测定,并对方法的检出限、精密度等指标进行分析。结果22种元素在各自测定范围内均有良好的线性关系(r=0.9991~0.9999),检出限为0.003μg/L~0.012 mg/L,批内精密度为0.5%~7.2%,批间精密度为0.4%~9.4%,平均回收率为80.6%~114.9%。结论ICP-MS法测定全血中22种元素的效果良好,方法操作快速、简单,可用于临床全血中多元素的检测。Objective To establish a method for the simultaneous determination of 22 elements,including beryllium,vanadium,chromium,manganese,iron,calcium,magnesium,barium,cobalt,cadmium,copper,zinc,arsenic,selenium,titanium,strontium,nickel,molybdenum,tin,antimony,thallium and lead,in whole blood by inductively coupled plasma mass spectrometry(ICP-MS).Methods In September 2023,the analysis conditions were determined by optimizing the detection mode of the instrument,the pretreatment mode and the dilution factor of the samples,etc.Whole blood samples were diluted with a mixture of 0.1%nitric acid and 0.05%triton X-100,and centrifuged at 2000 r/min by high-speed centrifuge for 2 min.The supernatant was taken into inductively coupled plasma mass spectrometer to determine the content of 22 elements,and the detection limit and precision of the method were analyzed.Results The 22 elements had a good linear relationship in their respective measurement ranges(r=0.9991-0.9999),the detection limit ranged from 0.003μg/L to 0.012 mg/L.The intra-batch precision ranged from 0.5%to 7.2%,the inter-batch precision ranged from 0.4%to 9.4%,and the average recoveries ranged from 80.6%to 114.9%.ConclusionI CP-MS method has a good effect on the determination of 22 elements in whole blood.The method is fast and simple,and can be used for clinical detection of multiple elements in whole blood.
关 键 词:元素 全血 质谱法 电感耦合等离子体质谱(ICP-MS)
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222