Revised in-depth meta-analysis on the efficacy of robot-assisted versus traditional free-hand pedicle screw insertion  

在线阅读下载全文

作  者:Sorayouth Chumnanvej Branesh M.Pillai Jackrit Suthakorn Siriluk Chumnanvej 

机构地区:[1]Neurosurgery Division,Department of Surgery,Faculty of Medicine Ramathibodi Hospital,Mahidol University,Bangkok,Thailand [2]Center for Biomedical and Robotics Technology(BART LAB),Faculty of Engineering,Mahidol University,Bangkok,Thailand [3]Department of Anesthesiology and Operating Room,Phramongkutklao Hospital,Bangkok,Thailand

出  处:《Laparoscopic, Endoscopic and Robotic Surgery》2024年第4期155-165,共11页腔镜、内镜与机器人外科(英文)

基  金:the Human Research Ethics Committee,Faculty of Medicine Ramathibodi Hospital,Mahidol University,IRB No.(COA.MURA2020/1934).

摘  要:Objective:Robot-assisted pedicle screw insertion has recently emerged as an alternative to the traditional free-hand technique.However,discrepancies in the accuracy of screw placement between the 2 methods have been highlighted by some comparative studies.This meta-analysis was conducted to synthesize evidence comparing these techniques.Methods:Searches were conducted in 5 electronic databases adhering to specific eligibility criteria for randomized and observational studies.The data were analyzed using RevMan software and the results are presented as odds ratios(ORs),mean differences,or standard mean differences(SMDs)with 95%confidence intervals(CIs).Our analysis included 12 studies(7 randomized trials and 5 observational studies,involving 883 patients and 4903 screws).Results:The results demonstrated a higher rate of Grade A Gertzbein and Robbins pedicle placement score(OR:1.77;95%CI:1.10e2.87),a lower rate of revision surgeries(OR:0.21;95%CI:0.09e0.52),and a shorter radiation exposure duration(SMD?1.38,95%CI:2.32 to0.44)in the robot-assisted group compared with the free-hand group.Nonetheless,the length of hospital stay,volume of intraoperative blood loss,postoperative visual analogue scale scores for back pain,and rate of wound infection were similar between the 2 groups.Significant heterogeneity was observed in some outcomes.Conclusion:Compared with the free-hand method,the robot-assisted technique provides greater accuracy and reduced radiation exposure.The efficacy of the robot-assisted technique is expected to improve further as experience with its use in surgery grows.

关 键 词:Robotic surgery Pedicle screw placement FREE-HAND FLUOROSCOPY META-ANALYSIS 

分 类 号:R65[医药卫生—外科学] TP242[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象