两种常用品牌双能X线骨密度仪应用标准化中国库的检出率对比  

Comparison of the detection rate of two commonly used brands of dual-energy X-ray bone densitometry in standardized Chinese database

在线阅读下载全文

作  者:轩艳姣 倪晓龙 孙鸣珂 程晓光 闫东 Xuan Yanjiao;Ni Xiaolong;Sun Mingke;Cheng Xiaoguang;Yan Dong(Department of Radiology,Beijing Jishuitan Hospital of Capital Medical University,Beijing 100035,China)

机构地区:[1]首都医科大学附属北京积水潭医院放射科,北京100035

出  处:《现代仪器与医疗》2024年第5期35-39,共5页Modern Instruments & Medical Treatment

基  金:北京市医院管理中心临床医学发展专项经费资助(ZYLX202107)。

摘  要:目的回顾分析某三甲医院两种常用品牌双能X线吸收测量仪(dual energy X-Ray absorptiometry,DXA)应用标准化中国库(依据近期研究成果,首次试用)前后的骨质疏松检出率差异,以验证该标准化数据库的使用效果。为实现不同品牌DXA T值标准化提供理论和数据支持。方法收集2021年6月11日-2022年10月20日GE-Prodigy以及2021年10月1日-2022年9月9日Hologic Horizon-W测量的门诊30岁以上中国患者的骨密度结果。分别获得腰椎(L_(1~4))和单侧髋应用“中国库”和“标准化中国库”的T值,并依据T值计算两种品牌DXA应用标准化数据库前后的检出率。结果两种品牌DXA应用标准化数据库前后的L_(1~4)检出率分别相差136.99%和4.58%;单侧髋检出率分别相差58.69%和22.99%。结论GE-Prodigy与Hologic Horizon-W对骨质疏松的检出率差异较大,标准化中国库的应用降低了这两种国内常用品牌DXA的检出率的差异,将很大程度上提高骨质疏松诊断的同质性。Objective The difference in the osteoporosis detection rate before and after the application of the standardized Chinese database(based on recent research results,the first trial)of two commonly used brands of dual-energy X-ray absorptiometer(DXA)in a third class hospital was reviewed and analyzed,so as to verify the application effect of the standardized database and provide theoretical and data support for the standardization of T values of different brands of DXA.Methods BMD results from out-patient Chinese patients over 30 years of age measured by GE-Prodigy from June 11,2021 to October 20,2022 and Hologic Horizon-W from October 1,2021 to September 9,2022 were collected.The T-values of lumbar spine(L_(1~4))and unilateral hip were obtained,and the detection rates of DXA before and after the application of the standardized database were calculated.Results The difference of L_(1~4) detection rates between the two brands before and after applying the standardized database was 136.99%and 4.58%,respectively.The detection rate of single hip was 58.69%and 22.99%respectively.Conclusion There were significant differences in the positive rates of osteoporosis between GE-Prodigy and Hologic Horizon-W.The application of standardized databases reduced the differences in positive rates between these two commonly used types of DXA devices in China and greatly improved the homogeneity of osteoporosis diagnosis.

关 键 词:骨密度 双能X射线吸收法 标准化数据库 检出率 

分 类 号:TH77[机械工程—仪器科学与技术] R197.39[机械工程—精密仪器及机械]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象