检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姚佳 谢立惠 高飞 刘静 李川 Yao Jia;Xie Lihui;Gao Fei;Liu Jing;Li Chuan(Department of Obstetrics and Gynecology,Langfang Adelburg Hospital,Langfang 065000,China;Department of Orthopedics,920th Hospital of the Chinese People's Liberation Army Joint Logistics Support Force,Kunming 650000,China)
机构地区:[1]廊坊爱德堡医院妇产科,廊坊065000 [2]中国人民解放军联勤保障部队第九二〇医院骨科,昆明650000
出 处:《现代仪器与医疗》2024年第5期62-66,共5页Modern Instruments & Medical Treatment
基 金:廊坊市科技局计划项目(2022013024)。
摘 要:目的分析微量输液泵在输注缩宫素引产中的使用效果。方法选取2022年1月-2024年1月在廊坊爱德堡医院进行分娩的100例足月单胎头位需要引产的产妇,根据不同干预方法分为对照组和观察组,每组产妇50例。其中对照组采用人工操作输液器阀输注缩宫素治疗完成引产,而观察组则采用微量输液泵输注缩宫素完成引产。实验结束后分析两组产妇产程时间、产后2h出血情况、新生儿Apgar评分、引产成功率。结果观察组产妇达规律宫缩时间和第一产程时间均短于对照组,差异有统计学意义(P<0.05)。两组第二、三产程时间,差异无统计学意义(P>0.05)。观察组产妇产后2h出血量为(157.24±9.10)ml,低于对照组的(204.31±9.220)ml,差异有统计学意义(P<0.05)。两组新生儿1分钟Apgar评分、5分钟Apgar评分和新生儿窒息(Apgar评分<7分)发生率比较,差异均无统计学差异(P>0.05)。观察组缩宫素误差发生率低于对照组,引产成功率高于对照组,差异有统计学意义(P<0.05)。结论微量输液泵在输注缩宫素引产中的合理使用可以有效提高产妇引产效果,同时可以降低产妇出血量,对于产妇引产有着良好帮助,因此医疗人员可以对该引产方式进行推广使用。Objective To analyze the eff ectiveness of micro infusion pump in the induction of labor by infusion of oxytocin.Methods A total of 100 full-term single fetus who needed to be induced in head position and delivered in Aibao Hospital of Langfang from January 2022 to January 2024 were selected and divided into a control group and an observation group based on diff erent intervention methods,with 50 cases in each group.The control group received manual infusion of oxytocin through the valve of the infusion set to complete the induction of labor,while the observation group received infusion of oxytocin through a micro infusion pump to complete the induction of labor.After the experiment,analyze the duration of labor,2-hour postpartum bleeding,neonatal Apgar score,and success rate of induced abortion in two groups of parturients.Results The time of regular contraction and the fi rst stage of labor in the observation group were shorter than those in the control group,the diff erence was statistically signifi cant(P<0.05).There was no signifi cant diff erence in the second and third stages of labor between the two groups(P>0.05).The 2h postpartum blood loss in the observation group was(157.24±9.10)ml,lower than that in the control group(204.31±9.220)ml,and the diff erence was statistically signifi cant(P<0.05).There were no signifi cant diff erences in the incidence of 1-minute Apgar score,5-minute Apgar score and neonatal asphyxia(Apgar score<7)between the two groups(P>0.05).The incidence of oxytocin error in the observation group was lower than that in the control group,and the success rate of labor induction was higher than that in the control group,the diff erence was statistically signifi cant(P<0.05).Conclusion The reasonable use of micro infusion pumps in the induction of labor with oxytocin infusion can eff ectively improve the induction eff ect of parturients,while reducing the amount of bleeding and providing good assistance for parturient induction.Therefore,medical personnel can promote the use of this ind
分 类 号:TH77[机械工程—仪器科学与技术] R318.6[机械工程—精密仪器及机械]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.145.125.13