窗式空调器轴流风叶破损失效分析及优化  

Failure analysis and optimization of axial flow fan blade damage in window air conditioner

在线阅读下载全文

作  者:鞠文宏 Ju Wenhong(Gree Electric Appliances,Inc.of Zhuhai)

机构地区:[1]珠海格力电器股份有限公司

出  处:《制冷与空调》2024年第10期10-15,共6页Refrigeration and Air-Conditioning

摘  要:结合产品流通运输环境,对窗式空调器在使用过程中出现的轴流风叶破损失效问题进行系统性分析,并利用有限元仿真分析手段对失效现象进行相关模拟验证,同时对该轴流风叶等相关零部件结构优化方案进行仿真对比分析,最终确定结构强度优化方案。Based on the product circulation and transportation environment,this paper systematically analyzed the failure of axial-flow fan when using window air conditioners,and simulated to validate the failure phenomenon by finite element simulation analysis.At the same time,the structural optimization schemes of axial-flow fan and other related components were simulated,analyzed and compared,and the structural strength optimization scheme was determined evenrually.

关 键 词:窗式空调器 轴流风叶 破损 结构强度 仿真 

分 类 号:TM9[电气工程—电力电子与电力传动]

 